logo
Telephone: 513.942.4007 Rose Scientific Inc.
Toll Free: 888.249.4074
Fax: 780.462.5776
Email: usasales@rosesci.com
 
Search  
Quote Request Quote Request
Rapid Response Rapid Response
 
Home Products Service Clearance Chemicals Products COVID-19    
Rapid Response or call Rose Scientific toll free at 1.888.249.4074
Send us an email message outlining any request and we will get back to you with the details!
Contact me Send information Quote request  
Your name Your email Your telephone number

Oxygen Sensors, Hamilton VisiFerm DO and VisiFerm DO B Optical

  Overview

The VisiFerm is the first optical sensor ever for the measurement of dissolved oxygen that has significant advantages compared to classical Clark cells because there is no electrolyte needed and the luminophore is embedded in a robust sensor cap. Typical applications are biotechnology, water treatment and monitoring as well as in breweries, wineries and soft drink processing. Available with the innovative Arc technology.

The VisiFerm DO B is designed for use in breweries, with an active brewery mode and Cleaning in Place (CIB) technology. The VisiFerm DO B brewery and CIP modes allow accurate measurements during fermentation, filtration and filling when calibration after each CIP is difficult.

The Beverly Portable DO instrument uses the VisiFerm DO B optical sensor with built in intelligence and provides excellent reliability for in line and laboratory use in small and midsize breweries. It satisfies IP67 watertight standards, has the stamina for 50 hours of continuous operation, and can be calibrated without removing the sensor.

VisiFerm™ DO sensors provide electrical interfaces: ECS (classical electrochemical sensor), standard analog (4–20 mA) and digital RS485 (Modbus RTU). These are built into each sensor and are supported directly from the sensor head. The analog 4–20 mA and digital RS485 interfaces do not require any additional equipment such as an amplifier or transmitter. The VisiFerm™ DO sensor also contains a temperature sensor (NTC 22 kΩ) for the compensation of temperature of the oxygen signal in ECS mode (simulation of a classical amperometric oxygen sensor by means of VisiFerm™ DO).

Features of the VisiFerm DO sensors:
  • Suitable for steam sterilization, autoclavation and CIP
  • Flow independent self-diagnostics
  • Electrolyte-free, so no leakages occur
  • No polarization time required
  • Easily replaceable sensor cap containing the sensing element
  • Digital and analog (4-20 mA) signal output
  • ECS-mode available (Clark cell simulation)

Specifications (Click here):  Oxygen Sensors, Hamilton VisiFerm DO and VisiFerm DO B Optical

NumberDescriptionPrice $
242450-02 VisiFerm DO 120 optical oxygen sensor, 120 mm
Inquire
242451-02 VisiFerm DO 160 optical oxygen sensor, 160 mm
Inquire
242452-02 VisiFerm DO 225 optical oxygen sensor, shaft length 215 mm
Inquire
242453-02 VisiFerm DO 325 optical oxygen sensor, 325 mm
Inquire
242454-02 VisiFerm DO 425 optical oxygen sensor, 425 mm
Inquire
243090 VisiFerm DO B 120 (ECS) optical oxygen sensor, 120 mm, for brewing applications, especially during fermentation, filtration and filling, with Cleaning in Place (CIP) and brewery modes for reliable measurements when calibration after CIP is difficult
Inquire
243091 VisiFerm DO B 225 (ECS) optical oxygen sensor, shaft length 215 mm, for brewing applications, especially during fermentation, filtration and filling, with Cleaning in Place (CIP) and brewery modes for reliable measurements when calibration after CIP is difficult
Inquire
243092 VisiFerm DO B 325 (ECS) optical oxygen sensor, 325 mm, for brewing applications, especially during fermentation, filtration and filling, with Cleaning in Place (CIP) and brewery modes for reliable measurements when calibration after CIP is difficult
Inquire
243093 VisiFerm DO B 425 (ECS) optical oxygen sensor, 425 mm, for brewing applications, especially during fermentation, filtration and filling, with Cleaning in Place (CIP) and brewery modes for reliable measurements when calibration after CIP is difficult
Inquire
242427 ODO Cap P0, contains embedded luminophore
270.00
243510 ODO Cap P1, contains embedded luminophore, designed for fermentation processes in which sterilization in place (SIP) is performed in media with higher amounts of lipophilic compounds
Inquire
243515 ODO Cap H0, contains embedded luminophore, for use with VisiPro DO Ex explosive environment optical sensors
Inquire
243500 ODO Cap H1, contains embedded luminophore, for DO Ex explosive environment sensors, designed for fermentation processes in which sterilization in place (SIP) is performed in media containing higher amounts of lipophilic compounds
Inquire
243505 ODO Cap H2, with a hygienic design for fermentation processes in which sterilization in place (SIP) is performed in media containing higher amounts of lipophilic compounds
Inquire
242411 USB-ModBus RS 485 converter
178.20
242410 VisiCal™ calibration and maintenance tool to calibrate VisiFerm DO and Arc sensors and monitor their status, VP 8 connectors allow installation between the sensor and a VP 8 sensor cable
773.30
243498 Arc Wireless Converter Modbus, for wireless communication from Hamilton Device Manager (HDM) to Arc sensors
Inquire
243499 Wireless Converter BT, designed for wireless communication between HDM (Hamilton Device Manager) and VisiPro DO Ex explosive environment sensors.
Inquire
242170 Arc Wi Sensor Adapter, is mounted between the VP head of an Arc sensor and a VP sensor cable, provides wireless communication with the Arc View Handheld
Inquire
243030 Arc Wi 2G Adapter, wireless Arc sensors to Process Control System
Inquire
242180 Arc View Handheld and Dock, communicate with up to 31 sensors wirelessly, or hard wire to one sensor through dock, monitor, calibrate, and configure
Inquire
355298-03 Arc Sensor Cable with M8 4-pole socket, for sensor connection to Arc View Handheld Dock, NA connector
Inquire
242412 4-20 mA galvanic isolating amplifier M1 Inquire
242413-03 VisiFerm D4 power adapter, connects VisiFerm DO in ECS mode to the cable of classical sterilizable oxygen sensor with four-pole plug, includes wall plug power supply, NA plug Inquire
355194-03 Demo cable VP 8 for demonstration of Arc sensors, with power supply, device end open, NA plug
237.60
238999-2767 VisiFerm Demo Cable (1 m. Applikon BNC Connector, Euro Plug power supply) 297.00
238999-2768 VisiFerm Demo Cable (1 m. New Brunswick AMP Connector, Euro Plug power supply) 334.80
238999-2766 VisiFerm Demo Cable (1 m. Sartorius-BBI Lemo Connector, Euro Plug power supply) Inquire
355217 Sensor cable VP8 I m
Inquire
355245-03 Sensor Power Cable for control systems or transmitters with AMP connector, NA plug, 2.5 m Inquire
355218 Sensor cable VP 8 3 m Inquire
355219 Sensor cable VP 8 5 m Inquire
355220 Sensor cable VP 8 I0 m Inquire
355221 Sensor cable VP 8 I5 m Inquire
355222 Sensor cable VP 8 20 m Inquire
238999-2394 Sensor cable VP8 I m Inquire
238999-1953 Sensor cable VP 8 3 m Inquire
238999-2395 Sensor cable VP 8 5 m Inquire
238999-2396 Sensor cable VP 8 I0 m Inquire
238999-2403 Sensor cable VP 8 I5 m Inquire
238999-2505 Sensor cable VP 8 20 m Inquire
355283 Sensor Cable M12 for sensors with standard M12 connector, device side open end, 3 m
Inquire
355284 Sensor Cable M12, open end, for connection to a data recorder, indicator, control unit or PCS (Process Control System) with analog I/O, 5 m Inquire
355285 Sensor Cable M12, open end, for connection to a data recorder, indicator, control unit or PCS (Process Control System) with analog I/O, 10 m Inquire
355288 Sensor Power Cable M12, includes a power adapter to supply sensor with operation power in non-hazardous environments, 3 m
Inquire
355245-03 Sensor Power Cable for systems or transmitters with Lemo connector, NA plug, 2.5 m Inquire
355258-03 Sensor Power Cable for systems or transmitters with Binder connector, NA plug, 4 m Inquire
355297-03 Sensor Power Cable for control systems or transmitters with BNC connector, NA plug, 1 m Inquire
355245-03 Sensor Power Cable for control systems or transmitters with AMP connector, NA plug, 2.5 m Inquire
817100 Beverly, Portable DO Optical Measurement with VisiFerm DO B sensor, designed for inline and laboratory use in small or midsize breweries as well as in the soft beverage industry, measuring range 4 ppb to 25 ppm DO, operating temperature 0 to 80°C, pressure range 0 to 10 bar, uses oxygen dependent luminescence quenching, IP67 waterproof, 222×142×322 mm
Inquire