Conductivity Sensors, Hamilton Conducell Low Conductivity, UPW, Standard and Broad Range

  Overview

Conducell conductivity sensors measure the ability of a solution to conduct a current. The higher the concentration of ions in the solution, the higher the conductivity, which is measured in microSiemens (mS). Unlike pH that only measures the concentration of hydrogen ions, conductivity measurements take into account all the ionic species present.

Conductivity measurements can be used to determine the concentration of a solution provided the dissolved species are known but will not differentiate between acid and base. A common use of conductivity measurement is found in CIP (clean-in-place) systems utilized in pharmaceutical and food applications, where specific concentrations of the cleaning solution are critical to the process.

The Conducell conductivity sensors feature a variety of connection, material and technology options. Two-pole sensors are available in either a low cost solution (2DC-PG) or for accurate measurements of solutions with extremely low or high ionic strength (PWSE Arc PG, PWSE Arc TC). Four-pole sensors have measurement linearity over a large range, no polarization effects, and are less sensitive to coating from contaminated samples. Conducell 4USF conductivity sensors with stainless steel electrodes are the most common and suitable for many applications.

Hamilon Arc technology is available with the Conducell PWSE Arc PG, PWSE Arc TC, and 4USF Arc in 120, 215, 325 and 425 mm shaft lengths. Arc sensors provide a full online wireless option for monitoring, configuration and calibration.. The Arc system eliminates the external transmitter and communicates directly with the Process Control System

Features of the Conducell conductivity sensors:
  • Available 2-pole sensors for UHP water applications
  • Sensors available with PG 13.5, Tuchenhagen Varivent DN50/60, Neumo BIOConnect and Triclamp 1.5” process connection
  • All PEEK and EPDM materials exposed to medium are FDA approved
  • Cleaning in place (CIP) mode for all but 2DC-PG
  • Built in temperature sensor
  • Very easy to clean
  • Available Arc technology for wireless connectivity

Specifications (Click here):  Conductivity Sensors, Hamilton Conducell Low Conductivity, UPW, Standard and Broad Range

NumberDescriptionPrice $
242730 Conducell PWSE Arc PG 13.5 2-pole conductivity sensor, for liquids with very low conductivity such as ultra-pure water, only available with Arc technology, process connection PG 13.5, electrical connector VP 8, 12 mm Ø, length 120 mm
Inquire
242720 Conducell PWSE Arc TC 1.5 2-pole conductivity sensor, for liquids with very low conductivity such as ultra-pure water, only available with Arc technology, process connection Triclamp 1.5”, electrical connector VP 8, 19 mm Ø, length 87 mm
Inquire
237610 Conducell 2DC-PG, simple 2-pole or 2 electrode sensor, best for clean solutions and non-critical applications, process connection PG 13.5, electrical connector 5 m open end, 12 mm Ø, length 120 mm
Inquire
242159 Conducell 4USF Arc 120, 4-pole conductivity sensor designed to be used in various sensor housings for process connection, process connection PG 13.5, electrical connector VP 8, very good linearity over a broad range of conductivities, can tolerate some contamination, 12 mm Ø, length 160 mm
Inquire
242160 Conducell 4USF Arc 225, 4-pole conductivity sensor designed to be used in various sensor housings for process connection, process connection PG 13.5, electrical connector VP 8very good linearity over a broad range of conductivities, can tolerate some contamination, 12 mm Ø, length 215 mm
Inquire
242161 Conducell 4USF Arc 325, 4-pole conductivity sensor designed to be used in various sensor housings for process connection, process connection PG 13.5, electrical connector VP 8, very good linearity over a broad range of conductivities, can tolerate some contamination, 12 mm Ø, length 325 mm
Inquire
242162 Conducell 4USF Arc 425, 4-pole conductivity sensor designed to be used in various sensor housings for process connection, process connection PG 13.5, electrical connector VP 8, very good linearity over a broad range of conductivities, can tolerate some contamination, electrical connector VP 8, 12 mm Ø, length 425 mm
Inquire
237620 Conducell 4USF-PG 120, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, process connection PG 13.5, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø, length 120 mm
Inquire
237627 Conducell 4UHF-PG 120, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, medium affected materials PEEK, EPDM, Hastelloy C, process connection PG 13.5, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø, length 120 mm
Inquire
237630 Conducell 4UTF-PG 120, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, medium affected materials PEEK, EPDM, titanium, process connection PG 13.5, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø, length 120 mm
Inquire
237640 Conducell 4USF-VV, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, process connection Tuchenhagen Varivent DN50/60, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø
Inquire
237650 Conducell 4USF-BC, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, process connection Neumo BIOConnect, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø
Inquire
237700-OP Conducell 4US-G125, 4-pole conductivity sensor with various O-ring positions, process connection G 1-1/4”, electrical connector 5 m open end, good linearity over a broad range of conductivities, 25 mm Ø, length 37 mm
Inquire
237750 Conducell 4US-T150-50, 4-pole conductivity sensor with various O-ring positions, process connection Triclamp 1.5”, electrical connector 5 m open end, good linearity over a broad range of conductivities, 24 mm Ø, length 50 mm
Inquire
237760 Conducell 4US-T150-100, 4-pole conductivity sensor with various O-ring positions, process connection Triclamp 1.5”, electrical connector 5 m open end, good linearity over a broad range of conductivities, 24 mm Ø, length 100 mm
Inquire
242411 USB-MedBus RS 485 converter, to connect with a PC
78.20
355194-03 Demo cable VP 8 for demonstration of Arc sensors, with power supply, device end open, NA plug, 1 m
Inquire
242180 Arc View Handheld and Dock, communicate with up to 31 sensors wirelessly, or hard wire to one sensor through dock, monitor, calibrate, and configure
Inquire
242176 Arc Sensor Cable with MS 4-pole socket, for sensor connection to Arc View Handheld Dock, 1 m
Inquire
242170 Arc Wi Sensor Adapter, is mounted between the VP head of an Arc sensor and a VP sensor cable, provides wireless communication with the Arc View Handheld
Inquire
355108 Sensor cable VP6, single coaxial, device side no connector (open end), I m Inquire
355109 Sensor cable VP 6, single coaxial, device side no connector (open end), 3 m Inquire
355110 Sensor cable VP 6, single coaxial, device side no connector (open end), 5 m Inquire
355111 Sensor cable VP 6, single coaxial, device side no connector (open end), I0 m Inquire
355112 Sensor cable VP 6, single coaxial, device side no connector (open end), 20 m Inquire
355217 Sensor cable VP8, double coaxial, device side no connector (open end), I m
Inquire
355218 Sensor cable VP 8, double coaxial, device side no connector (open end), 3 m Inquire
355219 Sensor cable VP 8, double coaxial, device side no connector (open end), 5 m Inquire
355220 Sensor cable VP 8, double coaxial, device side no connector (open end), I0 m Inquire
355221 Sensor cable VP 8, double coaxial, device side no connector (open end),I5 m Inquire
355222 Sensor cable VP 8, double coaxial, device side no connector (open end), 20 m Inquire
237931 Flow through cell PEEK TC 1.5”, facilitates insertion of Conducell 4US-T150-50 in pipework Inquire
237331-OP FlexiFit Bio housing, G 1-1/4”, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures Inquire
237380-OP FlexiFit U Bio housing, G 1-1/4”, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures Inquire
237341 FlexiFit TC 150-33 housing, TC 1.5”, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures Inquire
237344 FlexiFit VV-0 housing, Varivent, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures Inquire
237345 FlexiFit VV-15 housing, Varivent, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures Inquire