Sterilizers, Memmert Hot Air Natural Convection (SN Models), Forced Air (SF Models) and SingleDisplay or TwinDisplay Generation 2012

  Overview

Sterilization, not disinfection, of containers and instruments using the Memmert SN Natural Convection or SF Forced Air Hot Air Sterilizers can save lives, in a laboratory or a medical setting.

In the Memmert hot air sterilizers, the SetpointWAIT function insures that the program starts timing when the setpoint temperature has been reached. Precisely maintaining the sterilization time to completely kill off even highly resistant microorganisms is guaranteed at all times, irrespective of the sterilization load and chamber volume. The SetpointWait feature can also be used with additional, flexibly placed Pt100 temperature sensors. In this case, sterilization only begins when the setpoint temperature has been reached at all measurement points.

For the special application of depyrogenization, the Memmert Hot Air Sterilizer S is absolutely ideal.

From the broad selection of models, with both natural (SN) and forced air circulation (SF), and convenient, approved and tested options and accessories, it is possible to build a Memmert Hot Air Sterilizer S for every application.

A wide range of options for programming and documentation using interfaces are available as part of the Memmert Generation 2012 class of products, in both SingleDisplay and TwinDisplay models.

As much function as necessary, as much individuality as possible! Contact Rose Scientific to custom design the Memmert Universal Oven that does what it needs to do with the resources available.

The ordering number is assembled from the catalog numbers of the numerous options and accessories at the time the Incubator unit is ordered.

Memmert supplies a three-year guarantee for appliances, except for wear and tear parts

Features of the Hot Air SN and SF Sterilizers:
  • Temperature range up to 250°C
  • Reliable and repeatable sterilization
  • Model sizes from 32L to 749L
  • Choice of SingleDisplay or TwinDisplay
  • Choice of natural convection (SN) or forced air circulation (SF)
  • Multiple over temperature protection including a mechanical limiter switch
  • Numerous options including additional temperature sensors
  • Memmert Generation 2012 appliance options for programming and documentation


Specifications (Click here):  Sterilizers, Memmert Hot Air Natural Convection (SN Models), Forced Air (SF Models) and SingleDisplay or TwinDisplay Generation 2012

NumberDescriptionPrice $
SN30 Hot Air Sterilizer S Generation 2012 SN30, Natural convection, 32L, 115V, exterior dimensions (WxDxH) 585x434x704mm, interior dimensions 400x250x320mm, 48kg, 1 shelf provided, 3 shelves maximum
Inquire
SN30Plus Hot Air Sterilizer S Generation 2012 SN30Plus, Two High Definition TFT Color Displays, Natural convection, 32L, 115V, exterior dimensions (WxDxH) 585x434x704mm, interior dimensions 400x250x320mm, 48kg, 1 shelf provided, 3 shelves maximum
Inquire
SN55 Hot Air Sterilizer S Generation 2012 SN55, Natural convection, 53L, 115V, exterior dimensions (WxDxH) 585x514x784mm, interior dimensions 400x330x400mm, 57kg, 1 shelf provided, 4 shelves maximum
Inquire
SN55Plus Hot Air Sterilizer S Generation 2012 SN55Plus, Two High Definition TFT Color Displays, Natural convection, 53L, 115V, exterior dimensions (WxDxH) 585x514x784mm, interior dimensions 400x330x400mm, 57kg, 1 shelf provided, 4 shelves maximum
Inquire
SN75 Hot Air Sterilizer S Generation 2012 SN75, Natural convection, 74L, 115V, exterior dimensions (WxDxH) 585×514×944mm, interior dimensions 400×330×560mm, 66kg, 2 shelves provided, 6 shelves maximum
Inquire
SN75Plus Hot Air Sterilizer S Generation 2012 SN75Plus, Two High Definition TFT Color Displays, Natural convection, 74L, 115V, exterior dimensions (WxDxH) 585×514×944mm, interior dimensions 400×330×560mm, 66kg, 2 shelves provided, 6 shelves maximum
Inquire
SN110 Hot Air Sterilizer S Generation 2012 SN110, Natural convection, 108L, 115V, exterior dimensions (WxDxH) 745×584×864mm, interior dimensions 560×400×480mm, 78kg, 2 shelves provided, 5 shelves maximum
Inquire
SN110Plus Hot Air Sterilizer S Generation 2012 SN110Plus, Two High Definition TFT Color Displays, Natural convection, 108L, 115V, exterior dimensions (WxDxH) 745×584×864mm, interior dimensions 560×400×480mm, 78kg, 2 shelves provided, 5 shelves maximum
Inquire
SN160 Hot Air Sterilizer S Generation 2012 SN160, Natural convection, 161L, 115V, exterior dimensions (WxDxH) 745×584×1104mm, interior dimensions 560×400×720mm, 96kg, 2 shelves provided, 8 shelves maximum
Inquire
SN160Plus Hot Air Sterilizer S Generation 2012 SN160Plus, Two High Definition TFT Color Displays, Natural convection, 161L, 115V, exterior dimensions (WxDxH) 745×584×1104mm, interior dimensions 560×400×720mm, 96kg, 2 shelves provided, 8 shelves maximum
Inquire
SN260 Hot Air Sterilizer S Generation 2012 SN260, Natural convection, 256L, 115V, exterior dimensions (WxDxH) 824×684×1183mm, interior dimensions 640×500×800mm, 110kg, 2 shelves provided, 9 shelves maximum
Inquire
SN260 Plus Hot Air Sterilizer S Generation 2012 SN260Plus, Two High Definition TFT Color Displays, Natural convection, 256L, 115V, exterior dimensions (WxDxH) 824×684×1183mm, interior dimensions 640×500×800mm, 110kg, 2 shelves provided, 9 shelves maximum
Inquire
SN450 Hot Air Sterilizer S Generation 2012 SN450, Natural convection, 449L, 400V 3 phase, exterior dimensions (WxDxH) 1224×784×1247mm, interior dimensions 1040×600×720mm, 170kg, 2 shelves provided, 8 shelves maximum 8
Inquire
SN450Plus Hot Air Sterilizer S Generation 2012 SN450Plus, Two High Definition TFT Color Displays, Natural convection, 449L, 400V 3 phase, exterior dimensions (WxDxH) 1224×784×1247mm, interior dimensions 1040×600×720mm, 170kg, 2 shelves provided, 8 shelves maximum
Inquire
SN750 Hot Air Sterilizer S Generation 2012 SN750, Natural convection, 749L, 400V 3 phase, exterior dimensions (WxDxH) 1224×784×1726mm, interior dimensions 1040×600×1200, 217kg, 2 shelves provided, 14 shelves maximum
Inquire
SN750Plus Hot Air Sterilizer S Generation 2012 SN750Plus, Two High Definition TFT Color Displays, Natural convection, 749L, 400V three phase, exterior dimensions (WxDxH) 1224×784×1726mm, interior dimensions 1040×600×1200, 217kg, 2 shelves provided, 14 shelves maximum
Inquire
SF30 Hot Air Sterilizer S Generation 2012 SF30, Forced air convection, 32L, 115V, exterior dimensions (WxDxH) 585x434x704mm, interior dimensions 400x250x320mm, 48kg, 1 shelf provided, 3 shelves maximum
Inquire
SF30Plus Hot Air Sterilizer S Generation 2012 SF30Plus, Two High Definition TFT Color Displays, Forced air convection, 32L, 115V, exterior dimensions (WxDxH) 585x434x704mm, interior dimensions 400x250x320mm, 48kg, 1 shelf provided, 3 shelves maximum
Inquire
SF55 Hot Air Sterilizer S Generation 2012 SF55, Forced air convection, 53L, 115V, 585x514x784mm, interior dimensions 400x330x400mm, 57kg, 1 shelf provided, 4 shelves maximum
Inquire
SF55Plus Hot Air Sterilizer S Generation 2012 SF55Plus, Two High Definition TFT Color Displays, Forced air convection, 53L, 115V, exterior dimensions (WxDxH) 585x514x784mm, interior dimensions 400x330x400mm, 57kg, 1 shelf provided, 4 shelves maximum
Inquire
SF75 Hot Air Sterilizer S Generation 2012 SF75, Forced air convection, 74L, 115V, exterior dimensions (WxDxH) 585×514×944mm, interior dimensions 400×330×560mm, 66kg, 2 shelves provided, 6 shelves maximum
Inquire
SF75Plus Hot Air Sterilizer S Generation 2012 SF75Plus, Two High Definition TFT Color Displays, Forced air convection, 74L, 115V, exterior dimensions (WxDxH) 585×514×944mm, interior dimensions 400×330×560mm, 66kg, 2 shelves provided, 6 shelves maximum
Inquire
SF110 Hot Air Sterilizer S Generation 2012 SF110, Forced air convection, 108L, 115V, exterior dimensions (WxDxH) 745×584×864mm, interior dimensions 560×400×480mm, 78kg, 2 shelves provided, 5 shelves maximum
Inquire
SF110Plus Hot Air Sterilizer S Generation 2012 SF110Plus, Two High Definition TFT Color Displays, Forced air convection, 108L, 115V, exterior dimensions (WxDxH) 745×584×864mm, interior dimensions 560×400×480mm, 78kg, 2 shelves provided, 5 shelves maximum
Inquire
SF160 Hot Air Sterilizer S Generation 2012 SF160, Forced air convection, 161L, 115V, exterior dimensions (WxDxH) 745×584×1104mm, interior dimensions 560×400×720mm, 96kg, 2 shelves provided, 8 shelves maximum
Inquire
SF160Plus Hot Air Sterilizer S Generation 2012 SF160Plus, Two High Definition TFT Color Displays, Forced air convection, 161L, 115V, exterior dimensions (WxDxH) 745×584×1104mm, interior dimensions 560×400×720mm, 96kg, 2 shelves provided, 8 shelves maximum
Inquire
SF260 Hot Air Sterilizer S Generation 2012 SF260, Forced air convection, 256L, 115V, exterior dimensions (WxDxH) 824×684×1183mm, interior dimensions 640×500×800mm 110kg, 2 shelves provided, 9 shelves maximum
Inquire
SF260Plus Hot Air Sterilizer S Generation 2012 SF260Plus, Two High Definition TFT Color Displays, Forced air convection, 256L, 115V, exterior dimensions (WxDxH) 824×684×1183mm, interior dimensions 640×500×800mm, 110kg, 2 shelves provided, 9 shelves maximum
Inquire
SF450 Hot Air Sterilizer S Generation 2012 SF450, Forced air convection, 449L, 400V 3 phase, exterior dimensions (WxDxH) 1224×784×1247mm, interior dimensions 1040×600×720mm, 170kg, 2 shelves provided, 8 shelves maximum
Inquire
SF450Plus Hot Air Sterilizer S Generation 2012 SF450Plus, Two High Definition TFT Color Displays, Forced air convection, 449L, 400V 3 phase, exterior dimensions (WxDxH) 1224×784×1247mm, interior dimensions 1040×600×720mm, 170kg, 2 shelves provided, 8 shelves maximum
Inquire
SF750 Hot Air Sterilizer S Generation 2012 SF750, Forced air convection, 749L, 400V 3 phase, exterior dimensions (WxDxH) 1224×784×1726mm, interior dimensions 1040×600×1200, 217kg, 2 shelves provided, 14 shelves maximum
Inquire
SF750Plus Hot Air Sterilizer S Generation 2012 SF750Plus, Two High Definition TFT Color Displays, Forced air convection, 749L, 400V 3 phase, exterior dimensions (WxDxH) 1224×784×1726mm, interior dimensions 1040×600×1200, 217kg, 2 shelves provided, 14 shelves maximum
Inquire
A6 Extended over temperature protection option for SingleDisplay (SN, SF) devices using additional Pt100 for independent temperature monitoring Inquire
B0 Full sight insulating glass door
Inquire
K1 Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber), includes replacement of 2 standard grids by 2 reinforced grids, sizes 450 and 750 only Inquire
R8 Fresh-air filter (filtration efficiency 80 %) mounted at the bottom, for SF or SFPlus, for model sizes 260 or smaller a subframe or subframe on castors is required Inquire
R0 Interior lighting option, 15W for sizes up to 260, 2 × 15W for sizes 450 and larger
Inquire
FX Entry port option, 23mm Ø, for introducing connections at the side, can be closed by flap, position F0 for left center center, F1 for left center top, F2 for right center center, F3 for right center top, F4 for special position left side, F5 for special position right side
Inquire
F6 Entry port option, 23mm Ø, for introducing connections at the back, can be closed by flap, special position back side
Inquire
D6 Entry port option, 14mm Ø, for introducing connections at the back, can be closed by flap, special position back side
Inquire
F7 Entry port option, 38mm Ø, for introducing connections at the back, can be closed by flap, special position back side
Inquire
V3-S 4-20 mA current loop interface option (0 to +260°C corresponds to 4-20 mA) temperature controller actual value Inquire
V6-S 4-20 mA current loop interface option (0 to +260°C corresponds to 4-20 mA) temperature of a Pt100 sensor positioned flexibly in chamber (maximum 1 in SingleDisplay, 3 in TwinDisplay) Inquire
V4 Fan speed monitoring option, for SFPlus models only Inquire
D00132 Works calibration certificate option for 3 temperatures, +160°C,+180°C and +250°C Inquire
E28884 Stainless Steel Grid shelving (standard equipment) for model size 30
Inquire
E20164 Stainless Steel Grid shelving (standard equipment) for model sizes 55 and 75
Inquire
E20165 Stainless Steel Grid shelving (standard equipment) for model sizes 110 and 160
Inquire
E28891 Stainless Steel Grid shelving (standard equipment) for model size 260
Inquire
E20182 Stainless Steel Grid shelving (standard equipment) for model sizes 450 and 750
Inquire
E29767 Reinforced stainless steel grid shelving, maximum loading 60 kg, model sizes 110 and 160 Inquire
E29766 Reinforced stainless steel grid shelving, maximum loading 60 kg, model size 260 Inquire
B32190 Reinforced stainless steel grid shelving, maximum loading 60 kg, with guide bars and fixing screws, used only in connection with option K1, model sizes 450 and 750 Inquire
B29727 Perforated stainless steel shelf, 10 mm Ø holes, for model size 30
Inquire
B03916 Perforated stainless steel shelf, 10 mm Ø holes, for model sizes 55 and 75
Inquire
B00325 Perforated stainless steel shelf, 10 mm Ø holes, for model sizes 110 and 160
Inquire
B29725 Perforated stainless steel shelf, 10 mm Ø holes, for model size 260
Inquire
B00328 Perforated stainless steel shelf, 10 mm Ø holes, for model sizes 450 and 750
Inquire
B32191 Reinforced perforated stainless steel shelves, maximum loading 60 kg, with guide bars and fixing screws, used only in connection with option K1, for model sizes 450 and 750 Inquire
E02070 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model size 30
Inquire
E02072 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model sizes 55 and 75
Inquire
E02073 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model sizes 110 and 160
Inquire
E29726 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model size 260
Inquire
E02075 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model sizes 450 and 750
Inquire
B04356 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model size 30
Inquire
B04358 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model sizes 55 and 75
Inquire
B04359 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model sizes 110 and 160
Inquire
B29722 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model size 260
Inquire
B04362 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model sizes 450 and 750
Inquire
B2975X Wall bracket, X=5 for model size 30, X=6 for size 55 , X=7 for size 75 , X=8 for size 110, X=9 for size 160 (frame for mounting on wall)
Inquire
GA1Q5 One year guarantee extension, size 160 and smaller Inquire
GA2Q5 One year guarantee extension, size 260 and larger Inquire
B6 Door with safety lock option, Generation 2012
Inquire
D4 Process dependent door lock option (only for units with TwinDisplay), Generation 2012 Inquire
V5 Door open recognition option (only for units with TwinDisplay), Generation 2012 Inquire
B8 Door hinged on left option, Generation 2012 Inquire
H5 Potential-free contact option (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached), Generation 2012
Inquire
H6 Potential-free contact option for combination error message such as supply failure, sensor fault or fuse, Generation 2012
Inquire
H72 Potential-free contact option (24 V/2 A) with socket to NAMUR NE 28 for signal generation, controlled by program segment, for a total of three selectable functions to be activated, including control of such elements as audible and visual signals, exhaust motors, fans or stirrers (only for units with TwinDisplay), maximum 2 contacts for 1–ph. units, Generation 2012
Inquire
H74 Potential-free contact option (24 V/2 A) with socket to NAMUR NE 28 for signal generation, controlled by program segment, for a total of three selectable functions to be activated, including control of such elements as audible and visual signals, exhaust motors, fans or stirrers (only for units with TwinDisplay), maximum 4 contacts for 3–ph. units, Generation 2012 Inquire
H4 Flexible Pt100 option for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external load temperature recording, maximum 3 sensors, Generation 2012
Inquire
H8 Additional Pt100 temperature sensor option for positioning in chamber or load, for local temperature measurement (up to maximum of 3 additional sensors), measurements can be displayed, recorded in the integral ring store, documented with the AtmoCONTROL software or printed on an attached device, Generation 2012
Inquire
C3 MobileALERT option, notification by SMS in case of any error or alarm of the device, requires option H6 “floating contact for alarm”, Generation 2012 Inquire
A8-X Temperature restriction option (for UN/UF/UNplus/UFplus) temperature choice X = 60, 70, 80, 95, 100, 120, 160, 180, 200, 220 or 250°C, Generation 2012 Inquire
E06192 USB-Ethernet adapter, Generation 2012
Inquire
E06189 USB connection cable for computer interface, Generation 2012 Inquire
E29778 USB User-ID stick, prevents unauthorized access, only for units with TwinDisplay, Generation 2012 Inquire
E29780 USB stick with documentation software, AtmoCONTROL and operation manual, for products with SingleDisplay (standard for products with TwinDisplay), Generation 2012 Inquire
B29768 Set of four height adjustable feet (not for model 450 or larger sizes), Generation 2012 Inquire
B29744 Stacking set (4 pieces) for stacking of models of the same size (not for 160 or larger sizes), Generation 2012
Inquire
B20718 Plug-in tube extension (outer diam. 60.3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose), only models U, I, and S, Generation 2012
Inquire
B20719 Plug-in tube extension (outer diam. 60.3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, and S, Generation 2012
Inquire
B297XX-AS Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots, XX = 28 (model size 30), 30 (size 55), 32 (size 75), 34 (size 110), 36 (size 160), 38 (size 260), 40 (size 450) or 42 (size 750 and larger), Generation 2012
Inquire
B297XX Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots, XX = 29 (size 30), 31 (size 55), 33 (size 75), 35 (size 110), 37 (size 160), 39 (size 260), 41 (size 450) or 43 (size 750 and larger), Generation 2012
Inquire
B29745 Subframe for model size 30, adjustable to height 600 mm, Generation 2012
Inquire
B29747 Subframe for model size 55 or 75, adjustable to height 600 mm, Generation 2012
Inquire
B29749 Subframe for model size 110 or 160, adjustable to height 500 mm, Generation 2012
Inquire
B29751 Subframe for model size 260, adjustable to height 500 mm, Generation 2012
Inquire
B29753 Subframe for model size 450, adjustable to height 500 mm, Generation 2012
Inquire
B29746 Subframe on castors for model size 30, adjustable to height 660 mm, Generation 2012
Inquire
B29748 Subframe on castors for model size 55 or 75, adjustable to height 660 mm, Generation 2012
Inquire
B29750 Subframe on castors for model size 110 or 160, adjustable to height 560 mm, Generation 2012
Inquire
B33657 Subframe for model size 30, adjustable in height (height 130 mm, for example for units with fresh-air filter), Generation 2012 Inquire
B33659 Subframe for model size 55 or 75, adjustable in height (height 130 mm, for example for units with fresh-air filter), Generation 2012 Inquire
B33661 Subframe for model size 110 or 160, adjustable in height (height 130 mm, for example for units with fresh-air filter), Generation 2012 Inquire
B33664 Subframe for model size 260, adjustable in height (height 130 mm, for example for units with fresh-air filter), Generation 2012 Inquire
B29762 Castor frame, 2-part for model size 30, height 140mm, Generation 2012
Inquire
B29763 Castor frame, 2-part for model size 55 or 75, height 140mm, Generation 2012
Inquire
B29764 Castor frame, 2-part for model size 110 or 160, height 140mm, Generation 2012
Inquire
B29765 Castor frame, 2-part for model size 260, height 140mm, Generation 2012
Inquire
FDAQ1 AtmoCONTROL Software, meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA), base license for the control of one unit (only for units with TwinDisplay), Generation 2012 Inquire
FDAQ2 Integration of additional units (up to maximum 15 units) into an already existent FDA-software license (only for units with TwinDisplay), Generation 2012 Inquire
D00124 IQ document with works test data for chamber,OQ/PQ check list as support for validation by user, Generation 2012 Inquire
D00125 IQ/OQ document with works test data for chamber, including temperature distribution survey for one free-selectable temperature value, 9 measuring points to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by users, model size 30, Generation 2012 Inquire
D00127 IQ/OQ document with works test data for chamber, including temperature distribution survey for one free-selectable temperature value, 27 measuring points to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by users, model sizes 55 and larger, Generation 2012 Inquire
D00136 IQ/OQ document with works test data for chamber, including temperature distribution survey for one free-selectable temperature, humidity and light value. 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by user (models HPP and ICH ), model sizes 110, 260 and 750, Generation 2012 Inquire
D00137 IQ/OQ document with works test data for chamber, including temperature distribution survey for one free-selectable temperature, humidity and light value. 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by user (models HPP with light and ICH L), model sizes 110, 260 and 750, Generation 2012 Inquire
B04713 External measuring instrument with sensors for daylight and UV-light, Generation 2012 Inquire
B04714 External measuring instrument with sensors with additional head for temperature and humidity measurement, Generation 2012 Inquire