pH Electrodes, Hamilton EasyFerm Plus, Plus Arc, Bio, Bio Arc, Plus QRP Arc

  Overview

The EasyFerm Plus family of pH-and ORP-electrodes is ideal for Biotech applications, such as fermentations, in which autoclavations, steam sterilizations (SIP) and cleaning in place (CIP) procedures occur frequently. In combination with the space saving Hamilton Hygienic Socket or FlexiFit, the EasyFerm Plus fits perfectly in many kinds of fermenters and vessels. Available with the innovative Arc technology.

As with the EasyFerm Plus family, the EasyFerm Bio family of pH-electrodes is also ideal for Biotech applications, such as fermentations, in which autoclavations, steam sterilizations (SIP) and cleaning in place (CIP) procedures occur frequently. In addition, the EasyFerm Bio offers certified BIO-compatibility for the reference electrolyte as well as EHEDG certified cleanability. In combination with the space saving Hamilton Hygienic Socket or FlexiFit the EasyFerm Bio fits perfectly in many kinds of fermenters and vessels. Available with the innovative Arc technology.

The EasyFerm Plus ORP Arc is an electrochemical ORP (Oxidation Reduction Potential) sensor with integrated electronics, having the full Arc functionality (of a measuring device with self-diagnostics). The sensor is designed for applications with high demands for stable measurements in pharmaceutical industry, in biotechnology and in foods production. The sensor is equipped with a pre-pressurized reference system and high performance HP Coatramic Diaphragm, and a platinum ring, suitable for effective SIP. The EasyFerm Plus ORP Arc is not equipped with a pH glass membrane.

Features of the EasyFerm Electrodes:
  • Stable measurement signals after steam sterilization, autoclaving and CIP
  • Drift-free measurement
  • Ceramic diaphragm ensures sterility of the electrode
  • Available with various connector heads: S8, K8, VP 6, Memosens (Plus, Plus Arc, Plus QRP Arc) and Arc (VP 8)
  • ATEX-certificate for S8, K8, VP 6 and Memosens (Plus, Plus Arc, Plus QRP Arc)
  • Medium affected materials according to USP class VI
  • Cleanability tested and certified according to EHEDG criteria (Bio, Bio Arc)
  • Biocompatibility tested and certified by MDT (Bio, Bio Arc)


Specifications (Click here):  pH Electrodes, Hamilton EasyFerm Plus, Plus Arc, Bio, Bio Arc, Plus QRP Arc

NumberDescriptionPrice $
238625 EasyFerm Plus K8 120, 120 mm length, 12 mm Ø, electrical connector K8
Inquire
238630 EasyFerm Plus K8 160 160 mm length, 12 mm Ø, electrical connector K8
Inquire
238627 EasyFerm Plus K8 200, 200 mm length, 12 mm Ø, electrical connector K8
Inquire
238626 EasyFerm Plus K8 225, 225 mm length, 12 mm Ø, electrical connector K8
Inquire
238628 EasyFerm Plus K8 325, 325 mm length, 12 mm Ø, electrical connector K8
Inquire
238629 EasyFerm Plus K8 425, 425 mm length, 12 mm Ø, electrical connector K8
Inquire
238633 EasyFerm Plus VP 120, 120 mm length, 12 mm Ø, electrical connector VP6
Inquire
238634 EasyFerm Plus VP 225, 225 mm length, 12 mm Ø, electrical connector VP6
Inquire
238635 EasyFerm Plus VP 325, 325 mm length, 12 mm Ø, electrical connector VP6
Inquire
238632 EasyFerm Plus VP 360, 360 mm length, 12 mm Ø, electrical connector VP6
Inquire
242091 EasyFerm Plus Arc 120, 120 mm length, 12 mm Ø, electrical connector VP8
Inquire
242092 EasyFerm Plus Arc 225, 225 mm length, 12 mm Ø, electrical connector VP8
Inquire
242093 EasyFerm Plus Arc 325, 325 mm length, 12 mm Ø, electrical connector VP8
Inquire
242094 EasyFerm Plus Arc 425, 425 mm length, 12 mm Ø, electrical connector VP8
Inquire
243632 EasyFerm Bio VP 120, 120 mm length, 12 mm Ø, electrical connector VP6
Inquire
243633 EasyFerm Bio VP 225, 225 mm length, 12 mm Ø, electrical connector VP6
Inquire
243634 EasyFerm Bio VP 325, 325 mm length, 12 mm Ø, electrical connector VP6
Inquire
243635 EasyFerm Bio VP 425, 425 mm length, 12 mm Ø, electrical connector VP6
Inquire
243625 EasyFerm Bio K8 120, 120 mm length, 12 mm Ø, electrical connector K8
Inquire
243626 EasyFerm Bio K8 160, 160 mm length, 12 mm Ø, electrical connector K8
Inquire
243627 EasyFerm Bio K8 200, 200 mm length, 12 mm Ø, electrical connector K8
Inquire
243628 EasyFerm Bio K8 225, 225 mm length, 12 mm Ø, electrical connector K8
Inquire
243629 EasyFerm Bio K8 325, 325 mm length, 12 mm Ø, electrical connector K8
Inquire
243630 EasyFerm Bio K8 425, 425 mm length, 12 mm Ø, electrical connector K8
Inquire
242120 EasyFerm Bio Arc 120, 120 mm length, 12 mm Ø, electrical connector VP8
Inquire
242121 EasyFerm Bio Arc 225, 225 mm length, 12 mm Ø, electrical connector VP8
Inquire
242122 EasyFerm Bio Arc 325, 120 mm length, 12 mm Ø, electrical connector VP8
Inquire
242123 EasyFerm Bio Arc 425, 120 mm length, 12 mm Ø, electrical connector VP8
Inquire
243050 EasyFerm Plus QRP Arc 120, 120 mm length, 12 mm Ø, electrical connector VP8
Inquire
243051 EasyFerm Plus QRP Arc 225, 225 mm length, 12 mm Ø, electrical connector VP8
Inquire
243052 EasyFerm Plus QRP Arc 325, 325 mm length, 12 mm Ø, electrical connector VP8
Inquire
243053 EasyFerm Plus QRP Arc 425, 425 mm length, 12 mm Ø, electrical connector VP8
Inquire
243498 Arc Wireless Converter Modbus, for wireless communication from Hamilton Device Manager (HDM) to Arc sensors
Inquire
243030 Arc Wi 2G Adapter, for wireless communication Arc sensors to the Process Control System, includes additional internal galvanic isolator for enhanced signal quality
Inquire
243168-XX Arc ECS Adaptor pH/QRP converts the digital signal from the pH or QRP Arc electrochemical sensors to the classic mV signal, to connect to a classical measuring device, BNC
Inquire
243169-XX Arc ECS Adaptor pH/QRP converts the digital signal from the pH or QRP Arc electrochemical sensors to the classic mV signal, to connect to a classical measuring device, Open End
Inquire
242180 Arc View Handheld and Dock, communicate with up to 31 sensors wirelessly, or hard wire to one sensor through dock, monitor, calibrate, and configure
Inquire
241411 USB-ModBus RS 485 Converter, allows operator to monitor, calibrate Arc sensors and configure various parameters
Inquire
242170 Arc Wi Sensor Adapter, is mounted between the VP head of an Arc sensor and a VP sensor cable, provides wireless communication with the Arc View Handheld
Inquire