logo
Telephone: 513.942.4007 Rose Scientific Inc.
Toll Free: 888.249.4074
Fax: 780.462.5776
Email: usasales@rosesci.com
 
Search  
Quote Request Quote Request
Rapid Response Rapid Response
 
Home Products Service Clearance Chemicals Products COVID-19    
Rapid Response or call Rose Scientific toll free at 1.888.249.4074
Send us an email message outlining any request and we will get back to you with the details!
Contact me Send information Quote request  
Your name Your email Your telephone number

Pass-through Ovens UFP 600 TS and UFP 800 TS

  Overview

The pass-through UFP TS ovens are based on the Memmert standard ovens with the highest controller class (Perfect) and thus offer all technological highlights, such as heating adapted to specific products and the perfectly tuned control technology.

These units are designed to be custom built. Modular construction gives the flexibility to design a unit that has the technical features and accessories to meet any need. Part of Memmert Generation 2003.

For example, the UFP 800 TS can be equipped with lateral feed-through accommodating deflection rollers for a quick throughput and automatic loading when manufacturing electronic components.

The pass-through oven with two door panels on each side saves you time when loading and reduces the danger of contamination, especially when directly transporting the chamber load between a grey room and a clean room.


Features of the UFP600TS and UFP800TS Pass-through Ovens:
  • Temperature range up to 220 °C
  • Large capacity (interior volume 256L and 749L)
  • Highest performance class controller
  • Adjustable, forced air circulation
  • Two Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • Digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or start of ramp operation
  • Long-term logging (ring store) of all relevant data, GLP-conforming as data logger


Specifications (Click here):  Pass-through Ovens UFP 600 TS and UFP 800 TS

As much function as necessary, as much individuality as possible! Contact Rose Scientific to custom design the Memmert Pass-through Oven that does what it needs to do with the resources available. The ordering number is assembled from the catalog numbers of the various options at the time UFP TS is ordered. All Generation 2003 accessories are available.

NumberDescriptionPrice $
UFP600TS Universal oven, standard delivery pass-through version Model UFP600TS, 256L, supplied with two stainless steel grids
Inquire
UFP800TS Universal oven, standard delivery pass-through version Model UFP800TS, 749L, supplied with two stainless steel grids
Inquire
A5 Adjustable temperature limiter, safety device class 2 instead of adjustable overheat controller safety device class 3.1 Inquire
B0 Full-sight glass door (triple-insulating glass) for series UN/UF (extra)
Inquire
K1 Reinforced chamber - includes replacement of 2 standard shelves by 2 reinforced shelves total height increases by 20 mm (Model UFP600TS) or. by 45 mm (Model UFP800TS). Inquire
F0 Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left center cemter
Inquire
F1 Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left center top
Inquire
F2 Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right center center
Inquire
F3 Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right center top
Inquire
F4 Other port 23 mm diameter left, special position
Inquire
F5 Other port 23 mm diameter right, special position
Inquire
D4 Process-dependent electromagnetic door lock Inquire
D5 Locking mechanism with SPS control to prevent simultaneous opening of doors for contamination protection in case of wall installation Inquire
D00128 Works calibration certificate for three temperatures, +100°C, +160°C and +220°C
Inquire
E20167 Stainless Steel Grid (standard shelving) for UFP600TS
Inquire
E20182 Stainless Steel Grid (standard shelving) for UFP800TS
Inquire
E20183 Reinforced stainless steel grid, loading up to 60kg, with guide bars and fixing screws, only available with option K1, for UFP600TS Inquire
B32190 Reinforced stainless steel grid, loading up to 60kg, with guide bars and fixing screws, only available with option K1, for UFP800TS Inquire
B00326 Perforated stainless steel shelf, 10 mm Ø holes, for UFP600TS
Inquire
B00328 Perforated stainless steel shelf, 10 mm Ø holes, for UFP800TS
Inquire
E02068 Stainless steel slide in drip tray (non-perforated), 15 mm rim, (may affect the temperature distribution), cannot be used with option K1, for UFP600TS
Inquire
E02075 Stainless steel slide in drip tray (non-perforated), 15 mm rim, (may affect the temperature distribution), cannot be used with option K1, for UFP800TS
Inquire
B04359 Stainless Steel Bottom drip tray, cannot be used with option K1, for UFP600TS
Inquire
B04362 Stainless Steel Bottom drip tray, cannot be used with option K1, for UFP800TS
Inquire
B03190 Flush-fit unit (stainless steel frame covering gap between oven and wall opening), for UFP600TS Inquire
B03188 Flush-fit unit (stainless steel frame covering gap between oven and wall opening), for UFP800TS Inquire
W4 Interface Ethernet instead of RS232 inclusive software "Celsius Ethernet-Edition", Generation 2003 Inquire
W6 RS232 interface instead of USB, Generation 2003 Inquire
V2 Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface USB, Generation 2003 Inquire
B6 Locking door (security lock), Generation 2003 Inquire
R3 Interior socket, moisture tight for models IN, IF, IPP and ICP, not switchable, Generation 2003 Inquire
R4 Interior socket, moisture tight for models IN, IF, IPP and ICP, switchable, Generation, Generation 2003 Inquire
H4 Flexible Pt100 for positioning in chamber or in load with the socket in the front control panel, 4-pin according to NAMUR NE 28 for external temperature recording (load temperature), Generation 2003
Inquire
H8 Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer, .Generation 2003
Inquire
H5 Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (indication set point reached), Generation 2003
Inquire
H6 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse), Generation 2003
Inquire
H7 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by program segment for a total of 3 freely selected functions to be activated (such as acoustic and visual signals, exhaust motors, fans, and stirrers) (not available with interior lighting), Generation 2003
Inquire
A8 Temperature restriction (for UN and UF models), choice of temperature: 60, 70, 80, 95, 100, 120, 160, 180, 200, 220 or 250°C, Generation 2003 Inquire
E03643 USB connection cable for computer interface, Generation 2003 Inquire
E05300 Parallel -USB converter cable with integrated power supply unit to connect HP printers with USB interface to MEMMERT units, not applicable for UFP800DW, Generation 2003 Inquire
B04432 Documentation package consisting of parallel USB converter cable including PCL3-compatible HP color inkjet printer with USB interface (HP OfficeJet 6000 or successor) for direct connection of printer to Memmert unit, not applicable for UFP800DW, Generation 2003 Inquire
E05284 Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps, Generation 2003 Inquire
E04004 Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps), Generation 2003 Inquire
E04159 Oven-linked authorization card (User-ID-Card) prevents undesired manipulation by unauthorized third parties, specify serial number, Generation 2003 Inquire
E05019 Software conforming to FDA ”Celsius FDA Edition“ for up to 16 units. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA), not applicable for UFP800DW, Generation 2003 Inquire
FDAQ4 Integration of additional units (up to max.16 units) into an already existent FDA-software licence, not applicable for UFP800DW, Generation 2003 Inquire
D00103 IQ check list with works test data for chamber as support for validation by user. Generation 2003 Inquire
D00104 OQ check list with works test data for one free-selectable humidity and temperature value, including temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by user, Generation 2003 Inquire
D000117 OQ check list with works test data for one free-selectable humidity and temperature value, including temperature distribution survey for 5 measuring points to DIN 12880:2007-05 as support for validation by user, only for VO, VOcool, Generation 2003 Inquire
B04713 External measuring instrument with sensors for daylight and UV-light, not applicable for UFP800DW, Generation 2003 Inquire
B04714 External measuring instrument with additional measuring head for temperature and humidity measurement, not applicable for UFP800DW, Generation 2003 Inquire