Oxygen Sensors, Hamilton Oxysens, OxyFerm, and OxyGold Classic Amperometric and Trace Measurementv
Overview
The Oxysens, OxyFerm and OxyGold are classic electrochemical (amperometric) oxygen sensors.
The Oxysens is designed for the use in water, swimming pools and fish farms. This sensor uses a fixed cable and is insensitive to soiling. It requires no replacement of cathode, membrane or electrolyte.
The OxyFerm family of oxygen sensors are designed for the use in biotechnology applications, where
autoclavations, steam sterilizations and cleaning in place procedures occur frequently. Different membrane materials and membrane body shapes with protective or rounded edges are available.
The OxyFerm FDA sensors have a rounded FDA-approved silicone membrane. The XL models offer a 25 mm diameter shaft and a choice of o-ring placement. The OxyFerm sensors are available with the innovative Arc technology.
The OxyGold dissolved oxygen sensors are designed for applications with trace levels of oxygen such as boiler feed water or beverages. The B-versions have an acidic electrolyte and show no cross-sensitivity to carbon dioxide. Also available with the innovative Arc technology.
Features of the OxyFerm, OxyGold and Oxysens amperometric oxygen sensors:
A variety of choices, including with Arc technology
Shaft diameters of 12 mm or 25 mm (XL models)
XL models have various choices for o-ring position
Oxysens is insensitive to soiling and is maintenance free
FDA models have rounded FDA approved silicone membranes
OxyGold models are for trace level applications
Connector heads T82/D4, VP 6 and ARC (VP 8) available
ATEX certification for T82/D4 and VP 6c
Specifications (Click here):
Oxygen Sensors, Hamilton Oxysens, OxyFerm, and OxyGold Classic Amperometric and Trace Measurementv
Specifications
Model:
OxyFerm FDA Arc XL
OxyFerm FDA Arc XL
OxyFerm FDA Arc XL
OxyFerm FDA Arc XL
Length: (mm)
56
120, 160, 215, 325, 425
120, 215
215
ATEX Certification:
No
No
No
No
Accuracy at 25° C: (%-vol)
± 2
± 2
± 2
± 2
Analog Interface 1: (mA)
4 - 20 for DO, programmable
4 - 20 for DO, programmable
4 - 20 for DO, programmable
4 - 20 for DO, programmable
Analog Interface 2: (mA)
4 - 20 for temperature programmable
4 - 20 for temperature programmable
4 - 20 for temperature programmable
4 - 20 for temperature programmable
Analog Interface 1 and 2:
Galvanically not isolated, pulse width modulation 3.5 kHz
Galvanically not isolated, pulse width modulation 3.5 kHz
Galvanically not isolated, pulse width modulation 3.5 kHz
Galvanically not isolated, pulse width modulation 3.5 kHz
Autoclavable:
Yes
Yes
Yes
Yes
Baud Rate: (bd)
4800, 9600, 19200, 38400, 57600,115200
4800, 9600, 19200, 38400, 57600,115200
4800, 9600, 19200, 38400, 57600,115200
4800, 9600, 19200, 38400, 57600,115200
Cleaning in place mode (CIP):
Yes
Yes
Yes
Yes
Configurable values, DO:
mbar, %-sat, %-vol, μg/l, mg/l, ppb, ppm
mbar, %-sat, %-vol, μg/l, mg/l, ppb, ppm
mbar, %-sat, %-vol, μg/l, mg/l, ppb, ppm
mbar, %-sat, %-vol, μg/l, mg/l, ppb, ppm
Configurable values, temperature:
°C, °F, K
°C, °F, K
°C, °F, K
°C, °F, K
Diameter: (mm)
25
12
12
12
Digital RS485 Interface:
Modbus RTU, maximum 31 addresses
Modbus RTU, maximum 31 addresses
Modbus RTU, maximum 31 addresses
Modbus RTU, maximum 31 addresses
Drift at Room Temperature, constant conditions: (% per week)
<1
<1
<1
<1
Temperature sensor:
NTC 22 kOhm
NTC 22 kOhm
NTC 22 kOhm
NTC 22 kOhm
Electrical Connector:
VP 8
VP 8
VP 8
VP 8
Electrolyte:
Oxylyte
Oxylyte
Oxylyte B
Oxylyte G
Maximum CO2 partial pressure: (bar)v
0.01
0.01
0.01
0.01
Measurement Principle:
Electrochemical reduction of oxygen
Electrochemical reduction of oxygen
Electrochemical reduction of oxygen
Electrochemical reduction of oxygen
Measuring Range, DO: (ppb to ppm)
10 to 40
10 to 40
10 to 40
10 to 40
Measuring Range, pO2: (mbar)
0.2 to 1000
0.2 to 1000
0.2 to 1000
0.2 to 1000
Operating Temperature Range, analog interface: (°C)
0 to 110
0 to 110
0 to 110
0 to 110
Operating Temperature Range, digital interface: (°C)
0 to 130
0 to 130
0 to 130
0 to 130
Operating Voltage: (VDC)
7 to 30
7 to 30
7 to 30
7 to 30
Pressure Range: (bar)
0 to 4
0 to 4
0 to 12
0 to 12
Response Time t98% at 25°C, from air to nitgrogen: (s)
30 to 60
30 to 60
30 to 60
30 to 60
Process connection:
PG 13.5
PG 13.5
PG 13.5
PG 13.5
Steam Sterilizable:
Yes
Yes
no
Yes
Required flow: (m/s)
≥ 0.03
≥ 0.03
≥ 0.1
≥ 0.1
Specifications
Model:
Oxysens
OxyFerm
OxyFerm XL
OxyFerm VP
OxyGold B
OxyGold G
Length: (mm)
120
120, 160, 225
56, 125, 262
120, 160, 225, 325, 425
20, 215
20, 215
ATEX Certification:
CE 0035 II 1/2 G Ex ia IIC T4/T5/T6
CE 0035 II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb
CE 0035 II 1/2 G Ex ia IIC T4/T5/T6
CE 0035 II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb
No
CE 0035 II 1/2 G Ex ia IIC T4/T5/T6
Analog Interface 1: (mA)
-
-
-
-
-
-
Analog Interface 2: (mA)
-
-
-
-
-
-
Analog Interface 1 and 2:
-
-
-
-
-
-
Autoclavable:
no
Yes
Yes
Yes
no
Yes
Baud Rate: (bd)
-
-
-
-
-
-
Cleaning in place mode (CIP):
No
Yes
Yes
Yes
Yes
Yes
Configurable values, DO:
-
-
-
-
-
-
Configurable values, temperature:
-
-
-
-
-
-
Diameter: (mm)
12
12
12
12
12
12
Drift at Room Temperature, constant conditions: (% per week)
<1
<1
<1
<1
<1
<1
Temperature sensor:
NTC 22 kOhm
NTC 22 kOhm
NTC 22 kOhm
NTC 22 kOhm
NTC 22 kOhm
NTC 22 kOhm
Electrical Connector:
5 m cable, open end
T82/D4
T82/D4
VP 6
VP 6
VP 6
Electrolyte:
Oxylyte
Oxylyte
Oxylyte
Oxylyte
Oxylyte B
Oxylyte G
Maximum CO2 partial pressure: (bar)
0.01
0.01
0.01
0.01
12
0.01
Measurement Principle:
Electrochemical reduction of oxygen
Electrochemical reduction of oxygen
Electrochemical reduction of oxygen
Electrochemical reduction of oxygen
Electrochemical reduction of oxygen
Electrochemical reduction of oxygen
Measuring Range, DO: (ppb to ppm)
40 to 40
40 to 40
40 to 40
40 to 40
8 to 40
40 to 40
Measuring Range, pO2: (mbar)
0.8 to 1000
0.2 to 1000
0.2 to 1000
0.2 to 1000
0.2 to 1000
0.2 to 1000
Operating Temperature Range, analog interface: (°C)
0 to 60
0 to 130
0 to 130
0 to 130
0 to 130
0 to 130
Operating Temperature Range, digital interface: (°C)
-
-
-
-
-
-
Operating Voltage: (VDC)
-
-
-
-
-
-
Pressure Range: (bar)
0 to 4
0 to 4
0 to 4
0 to 4
0 to 12
0 to 12
Response Time t98% at 25°C, from air to nitgrogen: (s)
30 to 60
30 to 60
30 to 60
30 to 60
30 to 60
30 to 60
Process connection:
PG 13.5
PG 13.5
G 1-1/4”
PG 13.5
PG 13.5
PG 13.5
Steam Sterilizable:
No
Yes
Yes
Yes
No
Yes
Required flow: (m/s)
≥ 0.03
≥ 0.03
≥ 0.03
≥ 0.03
≥ 0.1
≥ 0.1
Number
Description
Price $
237150
Oxysens 120 oxygen sensor, length 120 mm, diameter 12 mm, 5 m open end cable, insensitive to soiling, maintenance free
485.64
237170
OxyFerm XL 150, length 125 mm, diameter 25 mm, OP 7 to 63 mm
2,026.92
237174
OxyFerm XL 300, length 262 mm, diameter 25 mm, OP 7 to 63
2,147.60
237175-25
OxyFerm XL, OP = 25 (for 25 mm o-ring position, standard),length 56 mm, diameter 25 mm
1,647.30
237175-OP
OxyFerm XL, choose OP = 22 to 55 mm (for o-ring position),x length 56 mm, diameter 25 mm
1,647.30
237450
OxyFerm FDA 120, T82/D4 electrical connector, rounded Optiflow FDA approved silicone membrane, length 160 mm, 12 mm diameter
1,396.50
237455
OxyFerm FDA 160, T82/D4 electrical connector, rounded Optiflow FDA approved silicone membrane, length 160 mm, 12 mm diameter
Inquire
237452
OxyFerm FDA 225, T82/D4 electrical connector, rounded Optiflow FDA approved silicone membrane, length 215 mm, 12 mm diameter
1,419.30
237453
OxyFerm FDA 325, T82/D4 electrical connector, rounded Optiflow FDA approved silicone membrane, length 325 mm, 12 mm diameter
Inquire
237454
OxyFerm FDA 425, T82/D4 electrical connector, rounded Optiflow FDA approved silicone membrane, length 425 mm, 12 mm diameter
Inquire
237544
OxyFerm FDA VP 425, rounded Optiflow FDA approved silicone membrane, length 425 mm, 12 mm diameter
Inquire
237543
OxyFerm FDA VP 325, rounded Optiflow FDA approved silicone membrane, length 325 mm, 12 mm diameter
Inquire
237542
OxyFerm FDA VP 225, rounded Optiflow FDA approved silicone membrane, length 215 mm, 12 mm diameter
Inquire
237541
OxyFerm FDA VP 160, rounded Optiflow FDA approved silicone membrane, length 160 mm, 12 mm diameter
Inquire
237540
OxyFerm FDA VP 120, rounded Optiflow FDA approved silicone membrane, length 160 mm, 12 mm diameter
Inquire
243104
OxyFerm FDA Arc 425, rounded Optiflow FDA approved silicone membrane, length 425 mm, 12 mm diameter
2,135.22
243103
OxyFerm FDA Arc 325, rounded Optiflow FDA approved silicone membrane, length 325 mm, 12 mm diameter
2,122.68
243102
OxyFerm FDA Arc 225, rounded Optiflow FDA approved silicone membrane, length 215 mm, 12 mm diameter
2,104.44
243101
OxyFerm FDA Arc 160, rounded Optiflow FDA approved silicone membrane, length 160 mm, 12 mm diameter
2,091.90
243140-25
OxyFerm FDA Arc XL, OP = 25 (for 25 mm o-ring position, standard), length 56 mm, diameter 25 mm
2,311.92
243140-OP
OxyFerm FDA Arc XL, choose OP = 22 to 55 mm (for o-ring position) length 56 mm, diameter 25 mm
2,311.92
243100
OxyFerm FDA Arc 120, rounded Optiflow FDA approved silicone membrane, length 120 mm, 12 mm diameter
2,067.96
237180
OxyGold B 120, trace measurement, 120 mm length, 12 mm diameter
Inquire
237185
OxyGold B 225, trace measurement, length 215 mm, 12 mm diameter
1,871.88
237395
OxyGold G 120, trace measurement, length 120 mm, 12 mm diameter
1,904.94
237396
OxyGold G 225, trace measurement, length 215 mm, 12 mm diameter
1,896.96
243111
OxyGold G Arc 225, trace measurement, length 215 mm, 12 mm diameter
1,931.16
243110
OxyGold G Arc 120,trace measurement, length 120 mm, 12 mm diameter
2,951.46
243116
OxyGold B Arc 225, trace measurement, length 215 mm, 12 mm diameter, acidic electrolyte, no cross-sensitivity to carbon dioxide
2,909.28
243115
OxyGold B Arc 120, trace measurement, length 120 mm, 12 mm diameter, acidic electrolyte, no cross-sensitivity to carbon dioxide
2,914.98
237135
OxyGold Membrane Kit, Optiflow membrane, EPDM (FDA approved) O-ring material, Medium affected materials are stainless steel1.4435, silicone and EPDM