logo
Telephone: 513.942.4007 Rose Scientific Inc.
Toll Free: 888.249.4074
Fax: 780.462.5776
Email: usasales@rosesci.com
 
Search  
Quote Request Quote Request
Rapid Response Rapid Response
 
Home Products Service Clearance Chemicals Products COVID-19    
Rapid Response or call Rose Scientific toll free at 1.888.249.4074
Send us an email message outlining any request and we will get back to you with the details!
Contact me Send information Quote request  
Your name Your email Your telephone number

Constant Climate Chambers, Memmert Peltier-cooled HPP Models, TwinDisplay Generation 2012

  Overview

The Memmert Constant Climate Chambers Models HPP110, HPP260 and HPP750 are designed for long term stability testing for pharmaceutical products in accordance with ICH (International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use) standards and for any other application that requires testing under conditions of long term, precisely controlled environmental simulation.

The Peltier technology used in the HPP Constant Climate Chambers provides heating, cooling, humidifying and dehumidifying quietly, with little vibration, in a compact appliance that conserves energy and is a much more acceptable long term laboratory companion than a compressor based appliance.

The temperature control from +5 ºC to +70 ºC, as well as the active humidification and dehumidification from 10% to 90% relative humidity, are optimally tuned to the requirements of stability tests for the manufacturers of pharmaceutical products.

The quietness of the HPP Constant Climate Chambers make them ideal for breeding insects and reptiles.

With the choice of an optional light module the HPP Constant Climate Chambers are well suited for applications such as seed germination, plant cultivation, or insect breeding, especially Drosophila breeding, under constant climate and daylight conditions. A choice of cold white light (5500 Kelvin) or a combination of cold white and warm light (2700 Kelvin), dimmable and with average intensity of 10000 Lux, is available, using energy efficient LED emitters.

Double doors are standard, an exterior door of stainless steel and an interior one of glass. This feature reduces the potential for contamination and drops or rises in temperature, yet gives an optimal view of a sensitive load through wide interior glass doors

A wide range of options for programming and documentation using interfaces are available as part of the Memmert Generation 2012 class of products. See IPP Peltier-cooled Incubators, ICP compressor cooled incubators, or Universal Ovens for ordering information on Generation 2012 appliance options.

As much function as necessary, as much individuality as possible! Contact Rose Scientific to custom design the Memmert HPP Constant Climate Chamber that does what it needs to do with the resources available.

The ordering number is assembled from the catalog numbers of the various options at the time the HPP Constant Climate Chamber is ordered.

Memmert supplies a three-year guarantee for appliances, except for wear and tear parts

Features of the HPP Constant Climate Chambers:
  • Temperature range up to +70 ℃
  • Digitally controlled active humidification and dehumidification up to 90%
  • Three compact model sizes (108L, 256L, 749L)
  • Standard double doors reduce the possibility of contamination and drops or rises in temperature, and at the same time allow an optimal view through wide-area interior glass doors
  • Generation 2012 TwinDisplay technology
  • Peltier heating for efficient, stable, precise and very economic long term tests
  • Extremely quiet operation
  • Choose internal light options for germination, plant cultivation or insect breeding applications


Specifications (Click here):  Constant Climate Chambers, Memmert Peltier-cooled HPP Models, TwinDisplay Generation 2012

NumberDescriptionPrice $
HPP110 Peltier Cooled Constant Climate Chamber HPP110 Generation 2012, Two High Definition TFT Color Displays, 108L, 115V, exterior dimensions (WxDxH) 745×674×864mm, interior dimensions 560×400×480mm, 80kg, 2 shelves provided, 5 shelves maximum
Inquire
HPP260 Peltier Cooled Constant Climate Chamber IPP260 Generation 2012, Two High Definition TFT Color Displays, 256L, 115V, exterior dimensions (WxDxH) 824×774×1183mm, interior dimensions 640×500×800mm, 122kg, 2 shelves provided, 9 shelves maximum
Inquire
HPP750 Peltier Cooled Constant Climate Chamber IPP750 Generation 2012, Two High Definition TFT Color Displays, 749L, 115V, exterior dimensions (WxDxH) 1224×874×1726mm, interior dimensions 1040×600×1200, 208kg, 2 shelves provided, 14 shelves maximum
Inquire
K1 Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber), includes replacement of 2 standard grids by 2 reinforced grids, model sizes 450 and 750 only Inquire
T7 Cold white 5500 Kelvin light module, light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for models 260 and 750, illumination strength 10000 Lux, program controlled dimming from 0 to 100 % (in 10 % steps), ramp programming in combination with temperature and humidity Inquire
T8 Cold white 5500 Kelvin plus warm white 2700 Kelvin light module, 10 LED light strips (5 alternating cold white light strips and 5 warm white light strips) arranged on the side wall of the interior, illumination strength 10000 LUX, program controlled dimming from 0 to 100% in 10 % steps, ramp programming in combination with temperature and humidity Inquire
R3 Interior socket option, switches off using On/Off switch but not individually, moisture tight Inquire
FX Entry port option, 23mm Ø, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, position F0 for left center center, F1 for left center top, F2 for right center center, F3 for right center top, F4 for special position left side, F5 for special position right side
Inquire
F6 Entry port option, 23mm Ø, for introducing connections at the back, moisture tight, can be closed by flap and silicon stopper, special position back side
Inquire
F7-Si Entry port option, 40mm Ø, for introducing connections at the back, moisture tight, can be closed by silicon stopper, F7-Si special position back side, for HPP260 and HPP750 Inquire
V3-HPP 0-20 mA current loop interface option (-10 to +80°C corresponds to 4-20 mA) temperature controller actual value Inquire
V6-HPP 0-20 mA current loop interface option (-10 to +80°C corresponds to 4-20 mA) temperature of a Pt100 sensor positioned flexibly in chamber (maximum 3 in TwinDisplay) Inquire
V4-HPP 0-20 mA current loop interface option (-10 to +80°C corresponds to 4-20 mA) humidity controller actual value (0 to 100% rh corresponds to 4-20 mA) Inquire
D00105 Works calibration certificate option for one pair of temperature and humidity values Inquire
E20165 Stainless Steel Grid shelving (standard equipment) for HPP110
Inquire
E28891 Stainless Steel Grid shelving (standard equipment) for HPP260
Inquire
E20182 Stainless Steel Grid shelving (standard equipment) for HPP750
Inquire
E29767 Reinforced stainless steel grid shelving, maximum loading 60 kg, model sizes 110 and 160 Inquire
E29766 Reinforced stainless steel grid shelving, maximum loading 60 kg, model size 260 Inquire
B32190 Reinforced stainless steel grid shelving, maximum loading 60 kg, with guide bars and fixing screws, used only in connection with option K1, model sizes 450 and 750 Inquire
B00325 Perforated stainless steel shelf, 10 mm Ø holes, for HPP110
Inquire
B29725 Perforated stainless steel shelf, 10 mm Ø holes, for HPP260
Inquire
B34727 Perforated stainless steel shelf, 10 mm Ø holes, for HPP750
Inquire
B32191 Reinforced perforated stainless steel shelves, maximum loading 60 kg, with guide bars and fixing screws, used only in connection with option K1, for HPP750
Inquire
E02073 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model sizes 110 and 160
Inquire
E29726 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model size 260
Inquire
B04359 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model sizes 110 and 160
Inquire
B29722 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model size 260
Inquire
B04362 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for model sizes 450 and 750
Inquire
B32371 Holder for water tank for mounting on the rear of the appliance or the wall (connection lead 0.5m), additional water tank included, for HPP110 or HPP260 (standard equipment for HPP750) Inquire
B04712 Central water supply Inquire
GA1Q5 One year guarantee extension, size 160 and smaller Inquire
GA2Q5 One year guarantee extension, size 260 and larger Inquire