Conductivity Sensors, Hamilton Conducell Low Conductivity, UPW, Standard and Broad Range
Overview
Conducell conductivity sensors measure the ability of a solution to conduct a current. The higher the concentration of ions in the solution, the higher the conductivity, which is measured in microSiemens (mS). Unlike pH that only measures the concentration of hydrogen ions, conductivity measurements take into account all the ionic species present.
Conductivity measurements can be used to determine the concentration of a solution provided the dissolved species are known but will not differentiate between acid and base. A common use of conductivity measurement is found in CIP (clean-in-place) systems utilized in pharmaceutical and food applications, where specific concentrations of the cleaning solution are critical to the process.
The Conducell conductivity sensors feature a variety of connection, material and technology options.
Two-pole sensors are available in either a low cost solution (2DC-PG) or for accurate measurements of solutions with extremely low or high ionic strength (PWSE Arc PG, PWSE Arc TC). Four-pole sensors have measurement linearity over a large range, no polarization effects, and are less sensitive to coating from contaminated samples. Conducell 4USF conductivity sensors with stainless steel electrodes are the most common and suitable for many applications.
Hamilon Arc technology is available with the Conducell PWSE Arc PG, PWSE Arc TC, and 4USF Arc in 120, 215, 325 and 425 mm shaft lengths. Arc sensors provide a full online wireless option for monitoring, configuration and calibration.. The Arc system eliminates the external transmitter and communicates directly with the Process Control System
Features of the Conducell conductivity sensors:
Available 2-pole sensors for UHP water applications
Sensors available with PG 13.5, Tuchenhagen Varivent DN50/60, Neumo BIOConnect and Triclamp 1.5” process connection
All PEEK and EPDM materials exposed to medium are FDA approved
Cleaning in place (CIP) mode for all but 2DC-PG
Built in temperature sensor
Very easy to clean
Available Arc technology for wireless connectivity
Specifications (Click here):
Conductivity Sensors, Hamilton Conducell Low Conductivity, UPW, Standard and Broad Range
Specifications
Model:
PWSE Arc PG, TC
4USF Arc 120, 225, 325, 425
4USF PG, VV, BC
2DC-PG
4UHF-PG, 4UTF-PG
4US G125, T150-50, T150-100
Length: (mm)
120 (PG), 87 (TC)
120, 215, 325, 425
120 (PG)
120
120
37 (G125), 50 (T150-50), 100 (T150-100)
Accuracy at 25 °C: (%)
± 3
-
-
-
-
-
Accuracy at 1 µS/cm to 100 mS/cm: (%)
-
± 3
-
-
-
-
Accuracy at 100 mS/cm to 300 mS/cm: (%)
-
± 5
-
-
-
-
Analog interface 1:
4-20 mA for conductivity, programmable
4-20 mA for conductivity, programmable
-
-
-
-
Analog interface 2:
4-20 mA for conductivity, programmable
4-20 mA for conductivity, programmable
-
-
-
-
Analog interface 1 and 2
Galvanically not isolated, pulse width modulation 3.5 kHz
Galvanically not isolated, pulse width modulation 3.5 kHz
-
-
-
-
ATEX Certification:
No
No
CE 0035 II 1/2 G Ex ia IIC T4/T5/T6 (PG), no (VV), no (BC)
G 1-1/4” (G125), Triclamp 1.5” (T150-50), Triclamp 1.5”
Steam sterilizable:
Yes
Yes, maximum temperature 140 °C
Yes
no
Yes
Yes
Temperature sensor:
NTC 22 kOHM
NTC 22 kOHM
Pt1000
Pt1000
Pt1000
Pt1000
Number
Description
Price $
242730
Conducell PWSE Arc PG 13.5 2-pole conductivity sensor, for liquids with very low conductivity such as ultra-pure water, only available with Arc technology, process connection PG 13.5, electrical connector VP 8, 12 mm Ø, length 120 mm
Inquire
242720
Conducell PWSE Arc TC 1.5 2-pole conductivity sensor, for liquids with very low conductivity such as ultra-pure water, only available with Arc technology, process connection Triclamp 1.5”, electrical connector VP 8, 19 mm Ø, length 87 mm
Inquire
237610
Conducell 2DC-PG, simple 2-pole or 2 electrode sensor, best for clean solutions and non-critical applications, process connection PG 13.5, electrical connector 5 m open end, 12 mm Ø, length 120 mm
Inquire
242159
Conducell 4USF Arc 120, 4-pole conductivity sensor designed to be used in various sensor housings for process connection, process connection PG 13.5, electrical connector VP 8, very good linearity over a broad range of conductivities, can tolerate some contamination, 12 mm Ø, length 160 mm
Inquire
242160
Conducell 4USF Arc 225, 4-pole conductivity sensor designed to be used in various sensor housings for process connection, process connection PG 13.5, electrical connector VP 8very good linearity over a broad range of conductivities, can tolerate some contamination, 12 mm Ø, length 215 mm
Inquire
242161
Conducell 4USF Arc 325, 4-pole conductivity sensor designed to be used in various sensor housings for process connection, process connection PG 13.5, electrical connector VP 8, very good linearity over a broad range of conductivities, can tolerate some contamination, 12 mm Ø, length 325 mm
Inquire
242162
Conducell 4USF Arc 425, 4-pole conductivity sensor designed to be used in various sensor housings for process connection, process connection PG 13.5, electrical connector VP 8, very good linearity over a broad range of conductivities, can tolerate some contamination, electrical connector VP 8, 12 mm Ø, length 425 mm
Inquire
237620
Conducell 4USF-PG 120, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, process connection PG 13.5, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø, length 120 mm
Inquire
237627
Conducell 4UHF-PG 120, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, medium affected materials PEEK, EPDM, Hastelloy C, process connection PG 13.5, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø, length 120 mm
Inquire
237630
Conducell 4UTF-PG 120, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, medium affected materials PEEK, EPDM, titanium, process connection PG 13.5, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø, length 120 mm
Inquire
237640
Conducell 4USF-VV, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, process connection Tuchenhagen Varivent DN50/60, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø
Inquire
237650
Conducell 4USF-BC, 4-pole conductivity sensor suited for hygienic applications, withstands CIP cleanings and autoclaving, process connection Neumo BIOConnect, electrical connector VP 6, good linearity over a broad range of conditions, 12 mm Ø
Inquire
237700-OP
Conducell 4US-G125, 4-pole conductivity sensor with various O-ring positions, process connection G 1-1/4”, electrical connector 5 m open end, good linearity over a broad range of conductivities, 25 mm Ø, length 37 mm
Inquire
237750
Conducell 4US-T150-50, 4-pole conductivity sensor with various O-ring positions, process connection Triclamp 1.5”, electrical connector 5 m open end, good linearity over a broad range of conductivities, 24 mm Ø, length 50 mm
Inquire
237760
Conducell 4US-T150-100, 4-pole conductivity sensor with various O-ring positions, process connection Triclamp 1.5”, electrical connector 5 m open end, good linearity over a broad range of conductivities, 24 mm Ø, length 100 mm
Inquire
242411
USB-MedBus RS 485 converter, to connect with a PC
78.20
355194-03
Demo cable VP 8 for demonstration of Arc sensors, with power supply, device end open, NA plug, 1 m
Inquire
242180
Arc View Handheld and Dock, communicate with up to 31 sensors wirelessly, or hard wire to one sensor through dock, monitor, calibrate, and configure
Inquire
242176
Arc Sensor Cable with MS 4-pole socket, for sensor connection to Arc View Handheld Dock, 1 m
Inquire
242170
Arc Wi Sensor Adapter, is mounted between the VP head of an Arc sensor and a VP sensor cable, provides wireless communication with the Arc View Handheld
Inquire
355108
Sensor cable VP6, single coaxial, device side no connector (open end), I m
Inquire
355109
Sensor cable VP 6, single coaxial, device side no connector (open end), 3 m
Inquire
355110
Sensor cable VP 6, single coaxial, device side no connector (open end), 5 m
Inquire
355111
Sensor cable VP 6, single coaxial, device side no connector (open end), I0 m
Inquire
355112
Sensor cable VP 6, single coaxial, device side no connector (open end), 20 m
Inquire
355217
Sensor cable VP8, double coaxial, device side no connector (open end), I m
Inquire
355218
Sensor cable VP 8, double coaxial, device side no connector (open end), 3 m
Inquire
355219
Sensor cable VP 8, double coaxial, device side no connector (open end), 5 m
Inquire
355220
Sensor cable VP 8, double coaxial, device side no connector (open end), I0 m
Inquire
355221
Sensor cable VP 8, double coaxial, device side no connector (open end),I5 m
Inquire
355222
Sensor cable VP 8, double coaxial, device side no connector (open end), 20 m
Inquire
237931
Flow through cell PEEK TC 1.5”, facilitates insertion of Conducell 4US-T150-50 in pipework
Inquire
237331-OP
FlexiFit Bio housing, G 1-1/4”, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures
Inquire
237380-OP
FlexiFit U Bio housing, G 1-1/4”, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures
Inquire
237341
FlexiFit TC 150-33 housing, TC 1.5”, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures
Inquire
237344
FlexiFit VV-0 housing, Varivent, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures
Inquire
237345
FlexiFit VV-15 housing, Varivent, for 120 mm sensors, 0-6 bar pressure range, -10 to 140°C temperature range, PG 13.5, suitable for autoclaving, CIP and SIP procedures