Incubators, Memmert Compressor-cooled ICP Models, TwinDisplay Generation 2012

  Overview

Memmert cooled incubators are used in all areas of microbiology, from environmental research and environmental protection to foodstuff examination, pharmacy and water engineering.

Memmert ICP Compressor-cooled incubators have advantages that make them the best choice for laboratory uses that require larger volumes with the need for rapid and precise alternating heating and cooling phases. The Memmert IPP Peltier-cooled incubators can be the choice for more compact, quiet and vibration free solutions with more moderate loads and temperature changes. The Memmert IPS Peltier-cooled incubators are the choice for longer term efficient storage or uses with stable temperatures.

Both the conventional ICP compressor-cooled incubators and the IPP or IPS models with Peltier technology incorporate a precise and well-proven Memmert control system for the controlled and documented storage and incubation of micro-organisms under real environmental conditions.

Through the finely adjusted control technology the temperature accurately reaches the setpoint without any intermediate energy spurts. All ICP incubators feature TwinDisplay.

Modular construction gives tremendous flexibility to custom design a unit that has the technical features and accessories to meet any need. All of the incubators feature double doors, with the interior one glass to provide a clear view without a drop in temperature. Easy to clean stainless steel interiors are strengthened with deep ribbing. Cooling and heating units are outside the working chamber inside the air jacket temperature control system, allowing for more uniform temperature control. A wide range of options for programming and documentation using interfaces are available as part of the Memmert Generation 2012 class of products.

Features of the ICP Compressor-cooled Incubators:
  • Temperature range up to + 60 ℃
  • Five ICP model sizes (53L to 749L)
  • State-of-the-art control technology with TwinDisplay
  • Double doors reduce the potential for contamination and drops in temperature, and offer an optimum view through the interior glass doors
  • Forced air circulation insures rapid energy transfer and optimum temperature distribution
  • Intelligent and efficient defrosting function
  • Working chamber is sealed off from the outside, allowing rapid and precise temperature control, no evaporator-related drying out of samples, no icing of the cooling unit, no de-humidification of the inner chamber
  • Options available as part of the Generation 2012 class of Memmert products


Specifications (Click here):  Incubators, Memmert Compressor-cooled ICP Models, TwinDisplay Generation 2012

NumberDescriptionPrice $
ICP55 Standard Delivery Compressor Cooled Incubator Generation 2012 ICP55, Two High Definition TFT Color Displays, 53L, 115V, exterior dimensions (WxDxH) 585x514x1153mm, interior dimensions 400x330x400mm, 89kg, 1 shelf provided, 4 shelves maximum
Inquire
ICP110 Standard Delivery Compressor Cooled Incubator Generation 2012 ICP110, Two High Definition TFT Color Displays, 108L, 115V, exterior dimensions (WxDxH) 745×584×1233mm, interior dimensions 560×400×480mm, 113kg, 2 shelves provided, 5 shelves maximum
Inquire
ICP260 Standard Delivery Compressor Cooled Incubator Generation 2012 ICP260, Two High Definition TFT Color Displays, 256L, 115V, exterior dimensions (WxDxH) 824×684×1552mm, interior dimensions 640×500×800mm, 157kg, 2 shelves provided, 9 shelves maximum
Inquire
ICP450 Standard Delivery Compressor Cooled Incubator Generation 2012 ICP450, Two High Definition TFT Color Displays, 449L, 115V, exterior dimensions (WxDxH) 1224×784×1613mm, interior dimensions 1040×600×729, 217kg, 2 shelves provided, 14 shelves maximum
Inquire
ICP750 Standard Delivery Compressor Cooled Incubator Generation 2012 ICP750, Two High Definition TFT Color Displays, 749L, 115V, exterior dimensions (WxDxH) 1224×784×1950mm, interior dimensions 1040×600×1200, 249kg, 2 shelves provided, 14 shelves maximum
Inquire
K1 Chamber modification to ICP450 or ICP750 for the application of reinforced perforated stainless steel shelves or stainless steel grids, includes the replacement of 2 standard grids by 2 reinforced grids Inquire
T7 Light module cold white 5500 Kelvin: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260 and 750, illumination strength 10,000 Lux, program controlled dimming from 0 to 100% (in 10% steps), ramp programming in combination with temperature and humidity Inquire
T8 Light module cold white 5500 Kelvin plus warm white 2700 Kelvin: LED light strips (5 resp. 7 alternating cold white light strips and 5 resp. 7 warm white light strips) on the side walls of the interior, for models 110 and larger, illumination strength 10,000 Lux, program controlled dimming from 0 to 100% (in 10% steps), ramp programming in combination with temperature and humidity Inquire
R3 Interior socket option, limits temperature range to maximum 70°C, switches off using On/Off switch but not individually Inquire
F0 Entry port option, 23mm Ø, for introducing connections at the side, can be closed by flap, position F0 for left center center, F1 for left center top
Inquire
F1 Entry port option, 23mm Ø, for introducing connections at the side, can be closed by flap, position F0 for left center center, F1 for left center top
Inquire
F3 Entry port option, 23mm Ø, for introducing connections at the side, can be closed by flap, position F3 for right center top, not for ICP55 or ICP110
Inquire
F7-Si Entry port option, 40mm Ø, for introducing connections at the back, moisture tight, can be closed by silicone stopper, F7-Si special position back side Inquire
V3 4-20 mA current loop interface option (0 to +90°C corresponds to 4-20 mA) temperature controller actual value Inquire
V6 4-20 mA current loop interface option (0 to +90°C corresponds to 4-20 mA) temperature of a Pt100 sensor positioned flexibly in chamber (maximum 1 in SingleDisplay, 3 in TwinDisplay) Inquire
V4 Fan speed monitoring Inquire
D00130 ICP Works calibration certificate option for 2 temperatures, 0°C and +37°C
Inquire
E20164 Stainless Steel Grid shelving (standard equipment) for ICP55
Inquire
E20165 Stainless Steel Grid shelving (standard equipment) for ICP110
Inquire
E28891 Stainless Steel Grid shelving (standard equipment) for ICP260
Inquire
E20182 Stainless Steel Grid shelving (standard equipment) for ICP450 and ICP750
Inquire
B32190 Reinforced stainless steel grid for ICP 450 and ICP 750, with guide bars and fixing screws, must be used only with option K1, maximum loading 60 kg Inquire
B03916 Perforated stainless steel shelf, 10 mm Ø holes, for ICP55
Inquire
B00325 Perforated stainless steel shelf, 10 mm Ø holes, for ICP110
Inquire
B29725 Perforated stainless steel shelf, 10 mm Ø holes, for ICP260
Inquire
B00328 Perforated stainless steel shelf, 10 mm Ø holes, for ICP450 and ICP750
Inquire
B32191 Reinforced perforated stainless steel shelf, for ICP450 and ICP750, with guide bars and fixing screws, must be used only with option K1, maximum. loading 60kg
Inquire
E02072 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for ICP55
Inquire
E02073 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for ICP110
Inquire
E29726 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for ICP260
Inquire
E02075 Slide in stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for ICP450 and ICP750
Inquire
B04358 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for ICP55
Inquire
B04359 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for ICP110
Inquire
B29722 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for ICP260
Inquire
B04362 Bottom stainless steel drip tray, 15mm rim, may affect temperature distribution, cannot be used with option K1, for ICP450 and ICP750
Inquire
B6 Door with safety lock option, Generation 2012
Inquire
D4 Process dependent door lock option (only for units with TwinDisplay), Generation 2012 Inquire
V5 Door open recognition option (only for units with TwinDisplay), Generation 2012 Inquire
B8 Door hinged on left option, Generation 2012 Inquire
H5 Potential-free contact option (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached), Generation 2012
Inquire
H6 Potential-free contact option for combination error message such as supply failure, sensor fault or fuse, Generation 2012
Inquire
H72 Potential-free contact option (24 V/2 A) with socket to NAMUR NE 28 for signal generation, controlled by program segment, for a total of three selectable functions to be activated, including control of such elements as audible and visual signals, exhaust motors, fans or stirrers (only for units with TwinDisplay), maximum 2 contacts for 1–ph. units, Generation 2012
Inquire
H74 Potential-free contact option (24 V/2 A) with socket to NAMUR NE 28 for signal generation, controlled by program segment, for a total of three selectable functions to be activated, including control of such elements as audible and visual signals, exhaust motors, fans or stirrers (only for units with TwinDisplay), maximum 4 contacts for 3–ph. units, Generation 2012 Inquire
H4 Flexible Pt100 option for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external load temperature recording, maximum 3 sensors, Generation 2012
Inquire
H8 Additional Pt100 temperature sensor option for positioning in chamber or load, for local temperature measurement (up to maximum of 3 additional sensors), measurements can be displayed, recorded in the integral ring store, documented with the AtmoCONTROL software or printed on an attached device, Generation 2012
Inquire
C3 MobileALERT option, notification by SMS in case of any error or alarm of the device, requires option H6 “floating contact for alarm”, Generation 2012 Inquire
A8-X Temperature restriction option (for UN/UF/UNplus/UFplus) temperature choice X = 60, 70, 80, 95, 100, 120, 160, 180, 200, 220 or 250°C, Generation 2012 Inquire
E06192 USB-Ethernet adapter, Generation 2012
Inquire
E06189 USB connection cable for computer interface, Generation 2012 Inquire
E29778 USB User-ID stick, prevents unauthorized access, only for units with TwinDisplay, Generation 2012 Inquire
E29780 USB stick with documentation software, AtmoCONTROL and operation manual, for products with SingleDisplay (standard for products with TwinDisplay), Generation 2012 Inquire
B29768 Set of four height adjustable feet (not for 450 or larger sizes), Generation 2012 Inquire
B29744 Stacking set (4 pieces) for stacking of models of the same size (not for 160 or larger sizes), Generation 2012
Inquire
B20718 Plug-in tube extension (outer diam. 60.3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose), only models U, I, and S, Generation 2012
Inquire
B20719 Plug-in tube extension (outer diam. 60.3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, and S, Generation 2012
Inquire
B297XX-AS Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots, XX = 28 (size 30), 30 (size 55), 32 (size 75), 34 (size 110), 36 (size 160), 38 (size 260), 40 (size 450) or 42 (size 750 and larger), Generation 2012
Inquire
B297XX Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots, XX = 29 (size 30), 31 (size 55), 33 (size 75), 35 (size 110), 37 (size 160), 39 (size 260), 41 (size 450) or 43 (size 750 and larger), Generation 2012
Inquire
B29745 Subframe for size 30, adjustable to height 600 mm, Generation 2012
Inquire
B29747 Subframe for size 55 or 75, adjustable to height 600 mm, Generation 2012
Inquire
B29749 Subframe for size 110 or 160, adjustable to height 500 mm, Generation 2012
Inquire
B29751 Subframe for size 260, adjustable to height 500 mm, Generation 2012
Inquire
B29753 Subframe for size 450, adjustable to height 500 mm, Generation 2012
Inquire
B29746 Subframe on castors for size 30, adjustable to height 660 mm, Generation 2012
Inquire
B29748 Subframe on castors for size 55 or 75, adjustable to height 660 mm, Generation 2012
Inquire
B29750 Subframe on castors for size 110 or 160, adjustable to height 560 mm, Generation 2012
Inquire
B33657 Subframe for size 30, adjustable in height (height 130 mm, for example for units with fresh-air filter), Generation 2012 Inquire
B33659 Subframe for size 55 or 75, adjustable in height (height 130 mm, for example for units with fresh-air filter), Generation 2012 Inquire
B33661 Subframe for size 110 or 160, adjustable in height (height 130 mm, for example for units with fresh-air filter), Generation 2012 Inquire
B33664 Subframe for size 260, adjustable in height (height 130 mm, for example for units with fresh-air filter), Generation 2012 Inquire
B29762 Castor frame, 2-part for size 30, height 140mm, Generation 2012
Inquire
B29763 Castor frame, 2-part for sizes 65 or 75, height 140mm, Generation 2012
Inquire
B29764 Castor frame, 2-part for size 110 or 160, height 140mm, Generation 2012
Inquire
B29765 Castor frame, 2-part for size 260, height 140mm, Generation 2012
Inquire
FDAQ1 AtmoCONTROL Software, meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA), base license for the control of one unit (only for units with TwinDisplay), Generation 2012 Inquire
FDAQ2 Integration of additional units (up to maximum 15 units) into an already existent FDA-software license (only for units with TwinDisplay), Generation 2012 Inquire
0124 IQ document with works test data for chamber,OQ/PQ check list as support for validation by user, Generation 2012 Inquire
D00125 IQ/OQ document with works test data for chamber, including temperature distribution survey for one free-selectable temperature value, 9 measuring points to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by users, model size 30, Generation 2012 Inquire
D00127 IQ/OQ document with works test data for chamber, including temperature distribution survey for one free-selectable temperature value, 27 measuring points to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by users, model sizes 55 and larger, Generation 2012 Inquire
D00136 IQ/OQ document with works test data for chamber, including temperature distribution survey for one free-selectable temperature, humidity and light value. 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by user (models HPP and ICH ), sizes 110, 260 and 750, Generation 2012 Inquire
D00137 IQ/OQ document with works test data for chamber, including temperature distribution survey for one free-selectable temperature, humidity and light value. 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by user (models HPP with light and ICH L), sizes 110, 260 and 750, Generation 2012 Inquire
B04713 External measuring instrument with sensors for daylight and UV-light, Generation 2012 Inquire
B04714 External measuring instrument with sensors with additional head for temperature and humidity measurement, Generation 2012 Inquire