Vacuum Drying Ovens, VO200 (29L), VO400 (49L) and VO500 (101L)
Overview
With short warming up times, high-precision temperature control and turbo-drying, the Memmert Vacuum Drying Ovens, VO200 (29L), VO400 (49L) and VO500 (101L), show off all their strength, yet at the same time they can dry heat-sensitive or oxygen-sensitive substances and materials such as cosmetics, food, clocks, books or PCBs and other electronic components with unparalleled gentleness.
The direct contact between chamber load and the heatable and removable thermal shelves guarantees in all vacuum oven VO models a quick and even temperature control without loss of heat. The direct heating contact results in fast and efficient operation.
Modular construction gives the flexibility to design a unit that has the technical features and accessories to meet any need. Memmert Generation 2003 accessories are available.
As much function as necessary, as much individuality as possible! Contact Rose Scientific to custom design the Memmert Vacuum Oven that does what it needs to do with the resources available. The ordering number is assembled from the catalog numbers of the various options at the time the Vacuum Oven is ordered
Features of the VO Vacuum Drying Ovens:
Temperature range up to +200 ℃
3 model sizes (29l, 49l and 1011) of vacuum oven VO
State-of-the-art control technology based on the Memmert P performance class for all models
Full sight anti-splinter, VDE-tested door construction for all models
Each of the aluminum thermoshelves is equipped with a separate shelf heating and its own sensors, with separate control circuits that react precisely to different loads and humidities
If large amounts of powder and granulate need to be dried, two vacuum values can be set, between which the pressure can oscillated under controlled conditions
Optional switching to inert gas: Programmable and digitally controlled inlet for inert gas with a flow rate reduction
Optional pump control: Optimized rinsing procedures for pump membranes as needed, as well as signal output for pumps ON/OFF
Specifications (Click here):
Vacuum Drying Ovens, VO200 (29L), VO400 (49L) and VO500 (101L)
Specifications
Model:
VO 200
VO 400
VO 500
Internal volume: (L)
29
49
101
Temperature range: (°C)
+ 5 above ambient to + 200
+ 20 to + 200
+ 20 to + 200
Temperature variation in time: (°C)
± 0.3
± 0.3
± 0.3
Temperature uniformity (surface) at 160°C, 50 mbar: (°C)
± 5
± 5
± 5
Vacuum pressure: (mbar)
10 to 1100
10 to 1100
10 to 1100
Permitted final vacuum: (mbar)
0.01
0.01
0.01
Maximum leakage rate: (bar/h)
0.01
0.01
0.01
Over temperature protection:
Triple protection. Including one mechanical
Triple protection. Including one mechanical
Triple protection. Including one mechanical
Under temperature protection:
Digitally adjustable, Memmert ASF sounds an alarm
Digitally adjustable, Memmert ASF sounds an alarm
Digitally adjustable, Memmert ASF sounds an alarm
Programmable digital timer:
7 day
7 day
7 day
Integrated timer for tempering and pressure profiles of up to 40 ramps, 1 m to 99 hrs, parameters:
Time, pressure and temperature, (setpoint dependent) individually adjustable for each segment
Time, pressure and temperature, (setpoint dependent) individually adjustable for each segment
Time, pressure and temperature, (setpoint dependent) individually adjustable for each segment
Digital display:
Temperature, day of week, time, pressure, setup values
Temperature, day of week, time, pressure, setup values
Temperature, day of week, time, pressure, setup values
Number of Pt100 temperature sensors:
1 per thermoshelf
1 per thermoshelf
1 per thermoshelf
Interior dimensions: W x D x H: (mm)
385 x 250 x 305
385 x 330 x 385
545 x 400 x 465
Maximum number of thermoshelves:
3
4
4
Supplied number of thermoshelves:
1
2
2
Calibration certificate for +160°C at 20 mbar:
Self-diagnostics
Self-diagnostics
Self-diagnostics
Calibration facility for temperature and pressure values:
Supplied for each supplied thermoshelf
Supplied for each supplied thermoshelf
Supplied for each supplied thermoshelf
xxxxx
Three freely selectable
Three freely selectable
Three freely selectable
Distance between thermoshelves: (mm)
75
75
75
Maximum load per shelf/ per oven: (kg)
20/40
20/60
20/60
Usable area of thermoshelf: W x D (mm)
365 x 210
365 x 230
525 x 380
Exterior dimensions: W x D x H: (mm)
550 x 400 x 600
550 x 480 x 680
710 x 550 x 760
Program stored in case of power failure:
yes
yes
yes
Depth of door handle: (mm)
38
38
38
Power: (V,Hz)
110V, 50/60Hz 230V, 50/60Hz
110V, 50/60Hz 230V, 50/60Hz
110V, 50/60Hz 230V, 50/60Hz
Weight: (kg)
58
82
120
Number
Description
Price $
VO200
Vacuum Drying Oven VO200, 29L, 110V, supplied with an aluminum thermoshelf, parallel/USB interface, Celsius software and MEMoryCARD
Inquire
VO400
Vacuum Drying Oven VO400, 49L, 110V, supplied with two aluminum thermoshelves, parallel/USB interface, Celsius software and MEMoryCARD.
Inquire
VO500
Vacuum Drying Oven VO500, 101L, 110V, supplied with two aluminum thermoshelves, parallel/USB interface, Celsius software and MEMoryCARD.
Inquire
T5
Premium VO module, includes the inert gas inlet W5, pump control, one printer interface, extra connectors for thermoshelves (one for VO200, two for VO400 or VO500), an additional thermoshelf for VO400 or VO 500 and a drip tray
Inquire
W5
Inert gas inlet: programmable and digitally controlled inlet for inert gas with flow rate reduction
Inquire
W8
Pump control: optimized rinsing procedures for the pump membranes as well as signal output for pump ON/OFF
Inquire
B00741
Additional thermoshelf made of aluminum #3.3547 (ASTM B209), with integrated large area heating including local temperature sensing (Pt100, 4 wire circuit), Multi-Level Over Temperature Control (MLOP) for each thermoshelf and calibration certificate (if ordered at the same time as the vacuum oven), for VO200
Inquire
B00743
Additional thermoshelf made of aluminum #3.3547 (ASTM B209), with integrated large area heating including local temperature sensing (Pt100, 4 wire circuit), Multi-Level Over Temperature Control (MLOP) for each thermoshelf and calibration certificate (if ordered at the same time as the vacuum oven), for VO400
Inquire
B00744
Additional thermoshelf made of aluminum #3.3547 (ASTM B209), with integrated large area heating including local temperature sensing (Pt100, 4 wire circuit), Multi-Level Over Temperature Control (MLOP) for each thermoshelf and calibration certificate (if ordered at the same time as the vacuum oven), for VO500
Inquire
B00733
Additional thermoshelf made of stainless steel #1.4404 (ASTM 316 L) for corrosive material , with integrated large area heating including local temperature sensing (Pt100, 4 wire circuit), Multi-Level Over Temperature Control (MLOP) for each thermoshelf and calibration certificate (if ordered at the same time as the vacuum oven), for VO200
Inquire
B00734
Additional thermoshelf made of stainless steel #1.4404 (ASTM 316 L) for corrosive material , with integrated large area heating including local temperature sensing (Pt100, 4 wire circuit), Multi-Level Over Temperature Control (MLOP) for each thermoshelf and calibration certificate (if ordered at the same time as the vacuum oven), for VO400
Inquire
B00735
Additional thermoshelf made of stainless steel #1.4404 (ASTM 316 L) for corrosive material , with integrated large area heating including local temperature sensing (Pt100, 4 wire circuit), Multi-Level Over Temperature Control (MLOP) for each thermoshelf and calibration certificate (if ordered at the same time as the vacuum oven), for VO500
Inquire
E04256
Removable bottom drip trays made of stainless steel 1.4404 (ASTM 316 L), for VO200
Inquire
E04257
Removable bottom drip trays made of stainless steel 1.4404 (ASTM 316 L), for VO400
Inquire
E04258
Removable bottom drip trays made of stainless steel 1.4404 (ASTM 316 L), for VO500
Inquire
E02030
Subframe, tubular steel, black enameled (for stacking unit consisting of vacuum oven and pump module, total height 1650 mm), W×D×H=529×383×450 mm, for VO200
Inquire
E02031
Subframe, tubular steel, black enameled (for stacking unit consisting of vacuum oven and pump module, total height 1650 mm), W×D×H=529×463×290 mm, for VO400
Inquire
E02037
Subframe, tubular steel, black enameled (for stacking unit consisting of vacuum oven and pump module, total height 1650 mm), W×D×H=689×533×130 mm, for VO500
Inquire
D00115
Works calibration certificate for the 3 temperatures +50°C, +100°C and +160°C at 20 mbar pressure
Inquire
GA2Q5
Guarantee extension on VO models for one year
Inquire
PM200
Noise insulated vacuum pump module without pump (for exterior dimensions and material see vacuum oven VO200) with antivibration metal plate at the bottom to accommodate the vacuum pump, includes full-sight glass door, socket, signal cable and connecting hose to the vacuum oven VO200
Inquire
PM400
Noise insulated vacuum pump module without pump (for exterior dimensions and material see vacuum oven VO400) with antivibration metal plate at the bottom to accommodate the vacuum pump, includes full-sight glass door, socket, signal cable and connecting hose to the vacuum oven VO400
Inquire
PM500
Noise insulated vacuum pump module without pump (for exterior dimensions and material see vacuum oven VO500) with antivibration metal plate at the bottom to accommodate the vacuum pump, includes full-sight glass door, socket, signal cable and connecting hose to the vacuum oven VO500
Inquire
PMP200-110
Noise insulated vacuum pump module PM200 with built-in pump, 110 V, includes energy-saving pump control (pump B04133 for VO 200 and pump B04134 for VO 400 and 500) W8 or T5 on VO necessary
Inquire
PMP400-110
Noise insulated vacuum pump module PM200 with built-in pump, 110 V, includes energy-saving pump control (pump B04133 for VO 200 and pump B04134 for VO 400 and 500) W8 or T5 on VO necessary
Inquire
PMP500-110
Noise insulated vacuum pump module PM200 with built-in pump, 110 V, includes energy-saving pump control (pump B04133 for VO 200 and pump B04134 for VO 400 and 500) W8 or T5 on VO necessary
Inquire
B04027
Signal cable (3 m) for optimizing pump performance by demand-controlled activation of purge of Memmert pump
Inquire
B04026
Vacuum connecting hose (3 m) from oven to Memmert pump, includes optimized connection accessories (partially stainless steel)
Inquire
B04133-110
Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures 34 Nl./min = 2,04 m³/h, automatic purge control from vacuum oven, #B04027 cable and #B04026 connecting hose necessary, 110 V, 50/60 Hz, guarantee period 2 years
Inquire
B04134-110
Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. Pressures 60 Nl./min = 3,6 m³/h, automatic purge control from vacuum oven,. #B04027 cable and $B04026 connecting hose necessary. 110 V, 50/60 Hz, guarantee period 2 years
Inquire
W4
Interface Ethernet instead of RS232 inclusive software “Celsius Ethernet-Edition”
Inquire
W6
RS232 interface instead of USB
Inquire
V2
Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface USB
Inquire
B6
Door with lock (safety lock, standard for sterilizers size 700 and 800, not available for VO, VOcool or TTC/CTC), Generation 2003
Inquire
R3
Interior socket, moisture tight for models IN/IF, IPP and ICP, not switchable, Generation 2003
Inquire
R4
Interior socket, moisture tight for models IN/IF, IPP and ICP, switchable with on/off switch in front panel, Generation 2003
Inquire
H4
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature)
Inquire
H8
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible), measured temperature canbe indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer (not available for VO, VOcool, TTC and CTC), Generation 2003
Inquire
H5
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached)
Inquire
H6
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse)
Inquire
H7
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) (not available with interior lighting)
Inquire
A8-XX
Temperature restriction (for UN/UF) Temperature XX = 60, 70, 80, 95, 100, 120, 160, 180, 200, 220 or 250°C, Generation 2003
Inquire
E03643
USB connection cable for computer interface
Inquire
E05300
Parallel/USB converter cable with integrated power supply unit to connect HP printers with USB interface to MEMMERT units, not applicable for UFP800DW, Generation 2003
Inquire
B004432
Documentation package consisting of parallel USB converter cable including PCL3-compatible HP colour inkjet printer with USB interface (HP OfficeJet 6000 or successor) for direct connection of printer to Memmert unit, not applicable for UFP800DW, Generation 2003
Inquire
E05284
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps
Inquire
E04004
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps)
Inquire
E04159
Oven-linked authorization card (User-ID-Card) prevents undesired manipulation by unauthorized third parties, if reordering specify serial number
Inquire
E05019
Software conforming to FDA ”Celsius FDA Edition“ for up to 16 units, meets the requirements for the use of electronically stored data sets and electronic signatures in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA), not applicable for UFP800DW, Generation 2003
Inquire
AQ4
Integration of additional units (up to max.16 units) into an already existent FDA-software licence, not applicable for UFP800DW, Generation 2003
Inquire
D00103
IQ check list with works test data for chamber as support for validation by customer
Inquire
D00104
OQ check list with works test data for one freely-selectable pair of humidity and temperature values, includes temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for user validation
Inquire
D00117
OQ check list with works test data for one freely-selectable pair of humidity and temperature values, includes temperature distribution survey for 5 measuring points to DIN 12880:2007-05 as support for user validation, only for VO or VOcool, Generation 2003
Inquire
B04713
External measuring instrument with sensors for daylight and UV-light
Inquire
B04714
External measuring instrument with additional measuring head for temperature and humidity measurement